We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch–filters were used as the light source for the calibration device. The overall uncertainty is 5%.
منابع مشابه
Multi-wavelength Calibration Procedure for the Pierre Auger Observatory Fluorescence Detectors
We present a method to measure the relative spectral response of the Pierre Auger Observatory Fluorescence Detector. The calibration was done at wavelengths of 320, 337, 355, 380 and 405 nm using an end-to-end technique in which the response of all detector components are combined in a single measurement. A xenon flasher and notch–filters were used as the light source for the calibration device...
متن کاملPerformance of the Fluorescence Detectors of the Pierre Auger
Fluorescence detectors of the Pierre Auger Observatory have been operating in a stable manner since January 2004. After a brief review of the physical characteristics of the detectors, the associated atmospheric monitoring, the calibration infrastructure and the detector aperture, we will describe the steps required for the reconstruction of fluorescence event data, with emphasis on the shower ...
متن کاملThe Lidar System of the Pierre Auger Observatory
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the origin of ultrahigh energy cosmic rays with energies above 1018 eV. The energy calibration of the detector is based on a system of four air fluorescence detectors. To obtain reliable calorimetric information from the fluorescence stations, the atmospheric conditions at the experiment’s site need to be monitored contin...
متن کاملar X iv : a st ro - p h / 06 09 06 3 v 1 3 Se p 20 06 The Lidar System of the Pierre Auger Observatory
The Pierre Auger Observatory in Malargüe, Argentina, is designed to study the origin of ultrahigh energy cosmic rays with energies above 1018 eV. The energy calibration of the detector is based on a system of four air fluorescence detectors. To obtain reliable calorimetric information from the fluorescence stations, the atmospheric conditions at the experiment’s site need to be monitored contin...
متن کاملAbsolute Calibration of the Auger Fluorescence Detectors
Absolute calibration of the Pierre Auger Observatory fluorescence detectors uses a light source at the telescope aperture. The technique accounts for the combined effects of all detector components in a single measurement. The calibrated 2.5 m diameter light source fills the aperture, providing uniform illumination to each pixel. The known flux from the light source and the response of the acqu...