Characterizing the selectivity of stationary phases and organic modifiers in reversed-phase high-performance liquid chromatographic systems by a general solvation equation using gradient elution.

نویسندگان

  • C M Du
  • K Valko
  • C Bevan
  • D Reynolds
  • M H Abraham
چکیده

Retention data for a set of 69 compounds using rapid gradient elution are obtained on a wide range of reversed-phase stationary phases and organic modifiers. The chromatographic stationary phases studied are Inertsil (IN)-ODS, pentafluorophenyl, fluoro-octyl, n-propylcyano, Polymer (PLRP-S 100), and hexylphenyl. The organic solvent modifiers are 2,2,2-trifluoroethanol (TFE); 1,1,1,3,3,3-hexafluoropropan-2-ol (HFIP); isopropanol; methanol (MeOH); acetonitrile (AcN); tetrahydrofuran; 1,4-dioxane; N,N-dimethylformamide; and mixed solvents of dimethylsulfoxide (DMSO) with AcN and DMSO with MeOH (1:1). A total of 25 chromatographic systems are analyzed using a solvation equation. In general, most of the systems give reasonable statistics. The selectivity of the reversed phase-high-performance liquid chromatographic (HPLC) systems with respect to the solute's dipolarity-polarity, hydrogen-bond acidity, and basicity are reflected in correspondingly large coefficients in the solvation equation. We wanted to find the most orthogonal HPLC systems, showing the highest possible selectivity difference in order to derive molecular descriptors using the gradient retention times of a compound. We selected eight chromatographic systems that have a large range of coefficients of interest (s, a, and b) similar to those found in water-solvent partitions used previously to derive molecular descriptors. The systems selected are IN-ODS phases with AcN, MeOH, TFE, and HFIP as mobile phase, PLRP-S 100 phase with AcN, propylcyano phase with AcN and MeOH, and fluorooctyl phase with TFE. Using the retention data obtained for a compound in the selected chromatographic systems, we can estimate the molecular descriptors with the faster and simpler gradient elution method.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

EVALUATION OF THE USE OF ANIONIC/ NONIONIC MIXED MICELLES IN REVERSED PHASE LIQUID CHROMATOGRAPHY OF CHLOROPHENOLS

The use of aqueous mixed micellar system consisting of sodium dodecyl sulfate (SDS) and polyoxyethylene (23) dodecanol (Brij-35) as the mobile phase in reversed-phase liquid chromatography was studied. A group of chlorophenols was used as the test mixture. Adding organic modifier to the system showed that the use of low concentrations of organic additives improves efficiency in SDS/Brij-35 mixe...

متن کامل

EFFECTS OF TEMPERATURE AND PERCENTAGE OF ORGANIC MODIFIER ON RETENTION AND SELECTIVITY IN RP-HPLC USING SOLVATION PARAMETER MODEL

Effects of temperature and percentage of organic modifier were studied on retention and selectivity in RP-HPLC using solvation parameter model. The system constants were determined by multiple linear regression analysis from experimental values in the retention factor for a group of different solutes with known descriptors by computer using the program SPSS/PC. The experimental results showed t...

متن کامل

Thermodynamics Study of Solvent Adsorption on Octadecyl-Modified Silica

Elution and solvation processes in liquid chromatography may be controlled by temperature changes. In the case of solvent adsorption, the temperature influences the amount of adsorbed solvent as well as the enthalpy and entropy of the solvation process. In this work, the thermodynamic parameters of organic solvents used as organic modifiers in the reversed-phase high-performance liquid chromato...

متن کامل

Review High-performance liquid chromatographic enantioseparation of drugs containing multiple chiral centers on chiral stationary phases

In recent years there has been considerable interest in the synthesis and separation of enantiomers of organic compounds especially because of their importance in the biochemistry and pharmaceutical industry. High-performance liquid Chromatography is a very useful method for the direct separation of enantiomers. However, about 30−40 years ago, commercially available chiral stationary phases wer...

متن کامل

Stationary Phases for LC Separations at Elevated Temperatures

Please direct correpsondence to Yu Yang at [email protected]. With the advent of column materials that can be used effectively at temperatures well over 100 °C, high temperature liquid chromatography (HTLC) separations have gained more attention in the last few years. Advantages of HTLC include fast analysis time, better selectivity, improved column efficiency, and minimization of the use of o...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of chromatographic science

دوره 38 11  شماره 

صفحات  -

تاریخ انتشار 2000