Effective mixing of laminar flows at a density interface by an integrated ultrasonic transducer.
نویسندگان
چکیده
An acoustic mixer for glass channel microfluidic systems is presented. An acoustic standing wave, perpendicular to the fluid flow, is generated by the excitation of a miniaturized piezoelectric transducer operated around 10 MHz. The transducer is fabricated into a planar printed circuit board structure, constituting the bottom channel wall, which makes the mixer simple to integrate with a wide selection of microfluidic channel designs. The mixing occurs at a fluid-fluid density interface due to the acoustic radiation force; an analytical expression is derived to qualitatively describe this phenomenon. Only a small density difference in the range of 2-5% is required to achieve 150-270% peak broadening of a fluorescent sample between sheath flows, which we use as a measure of the mixing efficiency. The mixing efficiency is measured with regard to its sensitivity to the density difference, the fluid velocity and the transducer driving frequency. Transducers at different positions along the microchannel make it possible to compare the mixing of straight versus diagonal flows across the transducer surface. We finally demonstrate enhanced chemical lysis of E. coli K12 cells in the device due to active fluid mixing.
منابع مشابه
Ultrasonic Transducers for Gas and Liquid Flow Metering
Accurate fluid flow metering is essential for modern process control, and ultrasonic flow meters are well established in this area. However, the specific acoustic impedance mismatch for most piezoelectric ultrasonic transducers is different when operating liquids and gases, hence there are problems measuring two-phase flows when using a single type of piezoelectric transducer in a flow meter. T...
متن کاملLaminar mixing of high-viscous fluids by a cylindrical chaotic mixer
Laminar mixing of glycerin in a chaotic mixer is carried by means of the blob deformation method. The mixer was a cylindrical vessel with two rotational blades which move along two different circular paths with a stepwise motion protocol. The flow visualization was performed by marking of the free surface of the flow with a tracer. The effects of controlling parameters such as rotational speed ...
متن کاملThe Interface Electronics for an Ultrasonic Matrix Transducer for 3d Transesophageal Echocardiography
In this paper, the design considerations of a mixed-signal integrated circuit for a 2D matrix ultrasonic transducer will be presented. The IC and the matrix transducer will be put into the tip of a transesophageal (TEE) probe for 3D echocardiography. The challenges associated with the interface electronics include: addressing the huge amount of elements, do the beam steering in the transmission...
متن کاملMicro-Fluidic Channels with Integrated Ultrasonic Transducers
This paper describes the work done in an attempt to integrate ultrasonic sensors in micro-fluidic channels. We have developed a system with fluidic channels having embedded zinc oxide transducers. A zinc oxide film is deposited on a glass substrate and is sandwiched between two electrodes. The transducers made are found to resonate at 400 MHz in thickness mode. The channels are made both from P...
متن کاملInvestigation of electrokinetic mixing in 3D non-homogenous microchannels
A numerical study of 3D electrokinetic flows through micromixers was performed. The micromixers considered here consisted of heterogeneous rectangular microchannels with prescribed patterns of zeta-potential at their walls. Numerical simulation of electroosmotic flows within heterogeneous channels requires solution of the Navier-Stokes, Ernest-Plank and species concentration equations. It is kn...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Lab on a chip
دوره 9 2 شماره
صفحات -
تاریخ انتشار 2009