Performance evaluation of two SiPMs arrays coupled to pixelated scintillations for PET/MR applications

نویسندگان

  • Maria Georgiou
  • Tomasz Szczesniak
  • Martyna Grodzicka
  • Eleftherios Fysikopoulos
  • George Loudos
چکیده

Technological Educational Institute of Athens, Athens, Greece The purpose of this study is to investigate the behavior of the new generation of SensL SiPM arrays, ArrayB and ArrayM, for PET/MR applications. The evaluation of the SiPMs performance underwent with pixelated GaGG and BGO scintillators with 2×2×5 mm pixel size and various coupling schemes for 511keV and 662keV energies. To acquire raw images, we used a symmetric resistive voltage division network and the 4x4 SiPMs anodes reduced to 2X and 2Y position signals. A FPGA Spartan 6 LX150T was used for triggering and digital processing of the pulses acquired using free running ADCs. The first step of our work was optimization of the bias voltage of the two SiPM arrays. The optimal bias voltage is a tradeoff between high photon detection efficiency and low excess noise factor. The SiPMs were coupled to homogeneous 16×16×10 mm CsITl scintillator and irradiated with Cs source. The energy resolution calculated in overvoltages between 26.5V and 30.5V for ArrayB and between 28.3V and 31.3V for ArrayM. The bias voltage with the best energy resolution was used for the evaluation of the SiPMs. The clear visualization of the GaGG and BGO crystal elements is expressed quantitatively by the mean peak-valley ratio of a horizontal profile in the raw images. The best optical coupling for the BGO was 2 mm thick glass. In the case of the GaGG 1 mm thick glass was adequate. The mean energy resolution of the GaGG scintillator is about two times better than the BGO for both type of SiPMs, after applying correction for their non-linear response. The low light output of the BGO scintillator in comparison with the GaGG as well as different emission spectra and the different PDE of the two types of SiPMs explain the differences in the behavior of the tested SiPMs arrays.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A large area, silicon photomultiplier-based PET detector module.

The introduction of silicon photomultipliers (SiPM) has facilitated construction of compact, efficient and magnetic field-hardened positron emission tomography (PET) scanners. To take full advantage of these devices, methods for using them to produce large field-of-view PET scanners are needed. In this investigation, we explored techniques to combine two SiPM arrays to form the building block f...

متن کامل

Evaluation of Pixelated NaI(Tl) Detectors for PET

A new detector design using pixelated NaI(Tl) crystals has been evaluated for use in positron emission tomography (PET). This detector uses 4 4 30 mm NaI(Tl) pixels coupled via a lightguide (1.4 cm thick) to an array of 39 mm diameter photomultiplier tubes (PMTs) in an Anger detector design. Our measurements show that the high light output of NaI(Tl) leads to a good discrimination of the 4 mm N...

متن کامل

Progress report on the MindView brain PET detector module based on large area SiPMs arrays

Institute for Instrumentation in Molecular Imaging, CSIC-UPV, Valencia, Spain The main technical goal of the MindView project and, thus, the subject of this contribution, is achieving simultaneous PET/MR imaging, dedicated to brain examination in clinical research settings to study psychiatric disorders. The system will allow visualization of the relevant structures in the brain with very high ...

متن کامل

A practical depth-of-interaction PET/MR detector with dichotomous-orthogonal-symmetry decoding

University of Texas MD Anderson Cancer Center, Houston, Texas, USA Conventional dual-end depth-of-interaction (DOI) PET detector readout requires two 2D SiPM arrays; with top and bottom SiPM reading the same pixel, there is information redundancy. We proposed a dichotomous-orthogonal-symmetric (DOS) dual-end DOI readout to eliminate this redundancy to significantly reduce SiPM usage, electronic...

متن کامل

4 th International Conference on Imaging Technologies in Biomedical Sciences

While the Anger gamma camera was dominant for several decades for nuclear medicine imaging, there are a number of significant developments in progress. The large increase of the usage of PET scanners has been a result of new detector materials such as LSO, GSO, YAP etc, improved electronics and algorithms such as list mode reconstruction and in particular the combination with CT. Finally althou...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 2  شماره 

صفحات  -

تاریخ انتشار 2015