A common HPLC-PDA method for amino acid analysis in insects and plants.

نویسندگان

  • M K Dhillon
  • Sandeep Kumar
  • G T Gujar
چکیده

A common method for analysis of 17 amino acids from various insect species and plant parts was standardized using HPLC-PDA. Prior to hydrolysis, lyophilization of test samples was found indispensible to remove excess moisture, which interferes in hydrolysis and separation of amino acids. After the hydrolysis of plant and insect samples, 500 and 100 microL of boiling HCl, respectively for reconstitution, and 20 microL of hydrolyzed samples used for derivatization, provided best results. Gradient profile of mobile phase and run time up to 65 min were standardized to (i) overcome the problems related to eluting underivatized sample part, (ii) optimize the use of mobile phase and run time, and (iii) get better separation of different amino acids. Analysis of Chilo partellus larvae reared on sorghum seedling powder based artificial diet indicated that arginine and histidine quantities were on par in both samples. However, methionine was higher, and leucine, isoleucine, lysine, phenylalanine, threonine and valine were lower in sorghum seedlings than in C. partellus larvae, suggesting compensation of these amino acids by the insect through voracious feeding, as is being expected from artificial diet. This method was found highly sensitive, reproducible and useful for the analysis of amino acids for better understanding of insect-plant interactions.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA

ABSTRACT        Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...

متن کامل

Simultaneous estimation of amlodipine besylate and nebivolol hydrochloride in pharmaceutical tablets formulation by RP-HPLC using PDA detector

Background: The present work was undertaken with the aim to develop and validate a rapid and consistent RP-HPLC method in which the peaks will be appear with short period of time as per ICH Guidelines. Materials and Methods: The separation was achieved on a a stainless steel analytical column, Eclipse XDB plus C18 column (4.6 X 150 mm; 5 μm) in an isocratic mode. The mobile phase w...

متن کامل

Optimization of a Dispersive Liquid-Liquid Microextration Method for Analysis of Chlorpyrifos in Urine Using the Chemometrics Method

Aims: The use of simple, low cost, high -efficiency extraction methods for sample preparation in the forensic toxicology has been considered. Nowadays, the chemometrics technique can be used to determine the influencing factors on the response to optimize extraction methods. The aim of this study was to design and optimize a dispersive liquid-liquid microextraction (DLLME) method for extraction...

متن کامل

Identification of chemical constituents in the extract and rat serum from Ziziphus jujuba Mill. by HPLC-PDA-ESI-MSn

Chinese jujube (Ziziphus jujuba Mill.) has long been widely used for human consumption and medicinal purposes in China. It has been reported to possess several vital biological activities. However, the systematic study on the chemical constituents absorbed into plasma and their metabolites is still insufficient. A high-performance liquid chromatography-photodiode array detector-electrospray ion...

متن کامل

Identification of chemical constituents in the extract and rat serum from Ziziphus jujuba Mill. by HPLC-PDA-ESI-MSn

Chinese jujube (Ziziphus jujuba Mill.) has long been widely used for human consumption and medicinal purposes in China. It has been reported to possess several vital biological activities. However, the systematic study on the chemical constituents absorbed into plasma and their metabolites is still insufficient. A high-performance liquid chromatography-photodiode array detector-electrospray ion...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Indian journal of experimental biology

دوره 52 1  شماره 

صفحات  -

تاریخ انتشار 2014