Self-focused ZnO transducers for ultrasonic biomicroscopy.
نویسندگان
چکیده
A simple fabrication technique was developed to produce high frequency (100 MHz) self-focused single element transducers with sputtered zinc oxide (ZnO) crystal films. This technique requires the sputtering of a ZnO film directly onto a curved backing substrate. Transducers were fabricated by sputtering an 18 μm thick ZnO layer on 2 mm diameter aluminum rods with ends shaped and polished to produce a 2 mm focus or f-number equal to one. The aluminum rod served a dual purpose as the backing layer and positive electrode for the resultant transducers. A 4 μm Parylene matching layer was deposited on the transducers after housing and interconnect. This matching layer was used to protect the substrate and condition the transfer of acoustic energy between the ZnO film and the load medium. The pulse-echo response for a representative transducer was centered at 101 MHz with a -6 dB bandwidth of 49%. The measured two way insertion loss was 44 dB. A tungsten wire phantom and an adult zebrafish eye were imaged to show the capability of these transducers.
منابع مشابه
Ultrahigh Frequency (100 MHz–300 MHz) Ultrasonic Transducers for Optical Resolution Medical Imagining
High resolution ultrasonic imaging requires high frequency wide band ultrasonic transducers, which produce short pulses and highly focused beam. However, currently the frequency of ultrasonic transducers is limited to below 100 MHz, mainly because of the challenge in precise control of fabrication parameters. This paper reports the design, fabrication, and characterization of sensitive broadban...
متن کاملHigh-intensity focused ultrasound treatment in refractory glaucoma patients: results at 1 year of prospective clinical study.
PURPOSE To evaluate the safety and efficacy of the ultrasonic circular cyclo-coagulation procedure using high-intensity focused ultrasound by a miniaturized annular device containing 6 piezoceramic transducers in patients with refractory glaucoma. METHODS This was a prospective interventional noncomparative study of 20 eyes of 20 patients with refractory glaucoma. All eyes were treated with 6...
متن کاملP-ZnO/n-Si Photodiodes Prepared by Ultrasonic Spraying Pyrolysis Method
ZnO ultraviolet (UV)/visible photodiodes were fabricated. The N-In codoped p-type ZnO films were deposited on (111)-oriented silicon substrate by ultrasonic spraying pyrolysis method. It was found the photocurrent approximately 3.9 10 A at a bias of 1 V and a photocurrent to dark current contrast ratio higher than around two orders of magnitude. The photodiodes exhibited two higher responsive r...
متن کاملImpact Analysis of Variation in Geometrical Features on Intrinsic Characteristics of Capacitive Micro-machined Ultrasonic Transducers
Capacitive Micro-machined Ultrasonic Transducers (CMUTs) are the ultrasonic devices which produce better features in contrast to piezoelectric transducers. The intrinsic parameter of CMUT varies with the variation in geometrical dimension of the device. The cavity height and the radius of the CMUT with circular membrane is varied in the lumped parallel plate model for its impact on the paramete...
متن کاملPiezoceramic Element Design and Fabrication for Ultrasonic Transducer of Gas Meter
Ultrasonic transducers play a significant role in generating and receiving the acoustic waves in ultrasonic flowmeters. Depending on the required accuracy, the ultrasonic transducers can be installed either in one pair or more in an ultrasonic flowmeter. The main part of an ultrasonic transducer is its piezoceramic element. In this work, four piezoceramic elements with different diameter to thi...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of applied physics
دوره 103 8 شماره
صفحات -