Comparing three UV wavelengths for pre‐exposing Gafchromic EBT2 and EBT3 films

نویسندگان

  • Toshizo Katsuda
  • Rumi Gotanda
  • Tatsuhiro Gotanda
  • Takuya Akagawa
  • Nobuyoshi Tanki
  • Tadao Kuwano
  • Kouichi Yabunaka
چکیده

Gafchromic films are used for X-ray dose measurements during diagnostic examinations and have begun to be used for three-dimensional X-ray dose measurements using the high-resolution characteristics of Gafchromic films for computed tomography. However, the problem of unevenness in Gafchromic film active layers needs to be resolved. Double exposures using X-rays are performed during therapeutic radiology, although this is difficult for a diagnostic examination because of a heel effect. Thus, it has been suggested that ultraviolet (UV) radiation be used as a substitute for X-rays. However, the appropriate UV wavelength has not been determined. Thus, we conducted this study to decide an appropriate UV wavelength. UV peak wavelengths of 245 nm (UV-A), 310 nm (UV-B), and 365 nm (UV-C) were used to irradiate EBT2 and EBT3 films. Each UV wavelength was irradiated for 5, 15, 30, and 60 min, and irradiation was then repeated every 60 min up to 360 min. Gafchromic films were scanned after every irradiation using a flatbed scanner. Images were split into RGB images, and red images were analyzed using ImageJ, version 1.44, image analysis software. A region of interest (ROI) one-half inch in diameter was placed in the center of subtracted Gafchromic film images, and UV irradiation times were plotted against mean pixel values. There were reactions in the front and back of Gafchromic EBT3 and the back of Gafchromic EBT2 with UV-A and UV-B. However, UV-C resulted in some reactions in both sides of Gafchromic EBT2 and EBT3. The UV-A and UV-B wavelengths should be used.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Correction of nonuniformity error of Gafchromic EBT2 and EBT3

This study investigates an X-ray dose measurement method for computed tomography using Gafchromic films. Nonuniformity of the active layer is a major problem in Gafchromic films. In radiotherapy, nonuniformity error is reduced by applying the double-exposure technique, but this is impractical in diagnostic radiology because of the heel effect. Therefore, we propose replacing the X-rays in the d...

متن کامل

Dosimetric characterization and use of GAFCHROMIC EBT3 film for IMRT dose verification

Radiochromic film has become an important tool to verify dose distributions in highly conformal radiation therapy such as IMRT. Recently, a new generation of these films, EBT3, has become available. EBT3 has the same composition and thickness of the sensitive layer of the previous EBT2 films, but its symmetric layer configuration allows the user to eliminate side orientation dependence, which i...

متن کامل

Characteristic of Gafchromic Film for Small Photon Field

Small photon field used in the intensity modulated radiotherapy (IMRT) and stereotactic radio surgery (SRS). It is difficult to measure beam profile and output factor because of electron disequilibrium, partial shutting of source because of this challenges, we need the good detector. This article is collection of 5 or more article and summary of the results of EBT3 that compared with EBT2 film ...

متن کامل

Intensities of Incident and Transmitted Ultraviolet-A Rays through Gafchromic Films

Gafchromic films have been applied to X-ray dosimetry in diagnostic radiology. To correct nonuniformity errors in Gafchromic films, X-rays in the double-exposure technique can be replaced with ultraviolet (UV)-A rays. Intensities of the incident and transmitted UV-A rays were measured. However, it is unclear whether the chemical color change of Gafchromic films affects the UV-A transmission int...

متن کامل

Dose-response curve of EBT, EBT2, and EBT3 radiochromic films to synchrotron-produced monochromatic x-ray beams.

PURPOSE This work investigates the dose-response curves of GAFCHROMIC(®) EBT, EBT2, and EBT3 radiochromic films using synchrotron-produced monochromatic x-ray beams. EBT2 film is being utilized for dose verification in photoactivated Auger electron therapy at the Louisiana State University Center for Advanced Microstructures and Devices (CAMD) synchrotron facility. METHODS Monochromatic beams...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 16  شماره 

صفحات  -

تاریخ انتشار 2015