Motion-compensated estimation of delivered dose during external beam radiation therapy: implementation in Philips' Pinnacle(3) treatment planning system.

نویسندگان

  • Shyam Bharat
  • Parag Parikh
  • Camille Noel
  • Michael Meltsner
  • Karl Bzdusek
  • Michael Kaus
چکیده

PURPOSE Recent research efforts investigating dose escalation techniques for three-dimensional conformal radiation therapy (3D CRT) and intensity modulated radiation therapy (IMRT) have demonstrated great benefit when high-dose hypofractionated treatment schemes are implemented. The use of these paradigms emphasizes the importance of smaller treatment margins to avoid high dose to surrounding normal tissue or organs at risk (OARs). However, tighter margins may lead to underdosage of the target due to the presence of organ motion. It is important to characterize organ motion and possibly account for it during treatment delivery. The need for real-time localization of dynamic targets has encouraged the use and development of more continuous motion monitoring systems such as kilo-voltage/fluoroscopic imaging, electromagnetic tracking, and optical monitoring systems. METHODS This paper presents the implementation of an algorithm to quantify translational and rotational interfractional and intrafractional prostate motion and compute the dosimetric effects of these motion patterns. The estimated delivered dose is compared with the static plan dose to evaluate the success of delivering the plan in the presence of prostate motion. The method is implemented on a commercial treatment planning system (Pinnacle(3), Philips Radiation Oncology Systems, Philips Healthcare) and is termed delivered dose investigational tool (DiDIT). The DiDIT implementation in Pinnacle(3) is validated by comparisons with previously published results. Finally, different workflows are discussed with respect to the potential use of this tool in clinical treatment planning. RESULTS The DiDIT dose estimation process took approximately 5-20 min (depending on the number of fractions analyzed) on a Pinnacle(3) 9.100 research version running on a Dell M90 system (Dell, Inc., Round Rock, TX, USA) equipped with an Intel Core 2 Duo processor (Intel Corporation, Santa Clara, CA, USA). The DiDIT implementation in Pinnacle(3) was found to be in agreement with previously published results, on the basis of the percent dose difference (PDD). This metric was also utilized to compare plan dose versus delivered dose, for prostate targets in three clinically acceptable treatment plans. CONCLUSIONS This paper presents results from the implementation of an algorithm on a commercially available treatment planning system that quantifies the dosimetric effects of interfractional and intrafractional motion in external beam radiation therapy (EBRT) of prostate cancer. The implementation of this algorithm within a commercial treatment planning system such as Pinnacle(3) enables easy deployment in the existing clinical workflow. The results of the PDD tests validate the implementation of the DiDIT algorithm in Pinnacle(3), in comparison with previously published results.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A validation of carbon fiber imaging couch top modeling in two radiation therapy treatment planning systems: Philips Pinnacle3 and BrainLAB iPlan RT Dose

BACKGROUND Carbon fiber (CF) is now the material of choice for radiation therapy couch tops. Initial designs included side metal bars for rigidity; however, with the advent of IGRT, involving on board imaging, new thicker CF couch tops without metal bars have been developed. The new design allows for excellent imaging at the expense of potentially unacceptable dose attenuation and perturbation....

متن کامل

Evaluation of Accuracy and Quality assurance of external beam therapy with photons

Introduction: Receiving exact dose by the patients is vital in radiotherapy. In radiation therapy, the dosimetry of radiations is too important because of successful radiation inquires for delivering the exact dose to the target volume. This study is to evaluate the tolerances and the accuracy of calculated dose of photon beams in the treatment software system. The TECDOC1583 p...

متن کامل

Investigation of tumor motion influence on applied dose distribution in conventional proton therapy vs. IMPT a 4D Monte Carlo simulation study

Background: in radiation treatment of moving targets located in thorax region of patient body, the delivered dose does not match with the planned treatment, resulting in some over and under dosage in the tumor volume, as a function of motion magnitude and frequency. Several efforts have been done to investigate the target motion effects on dose distribution in the target and surrounding normal ...

متن کامل

Commissioning kilovoltage cone‐beam CT beams in a radiation therapy treatment planning system

The feasibility of accounting of the dose from kilovoltage cone-beam CT in treatment planning has been discussed previously for a single cone-beam CT (CBCT) beam from one manufacturer. Modeling the beams and computing the dose from the full set of beams produced by a kilovoltage cone-beam CT system requires extensive beam data collection and verification, and is the purpose of this work. The be...

متن کامل

A quantitative investigation on lung tumor site on its motion tracking in radiotherapy with external surrogates

Introduction: In external beam radiotherapy each effort is done to deliver 3D dose distribution onto the tumor volume uniformly, while minimizing the dose to healthy organs at the same time. Radiation treatment of tumors located at thorax region such as lung and liver has a challenging issue during target localization since these tumors move mainly due to respiration. There are...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Medical physics

دوره 39 1  شماره 

صفحات  -

تاریخ انتشار 2012