Radiation dose estimates in humans for (11)C-acetate whole-body PET.

نویسندگان

  • Marc A Seltzer
  • Shamim A Jahan
  • Richard Sparks
  • David B Stout
  • Nagichettiar Satyamurthy
  • Magnus Dahlbom
  • Michael E Phelps
  • Jorge R Barrio
چکیده

UNLABELLED 11C-Acetate is currently being investigated as a new tracer for imaging neoplasms, most notably prostate cancer and its metastases. Previously reported dose estimates for (11)C-acetate prepared by the Oak Ridge Institute for Science and Education (ORISE) were based on a simple 3-compartment model in which all activity not measured in blood or excretion via breath was assumed to reside in the heart. Because all organs are involved in acetate metabolism to some extent, these estimates might overestimate heart and underestimate other organ dosimetry. Dynamic whole-body (11)C-acetate PET was therefore performed on 6 healthy human volunteers. Measured dose estimates for all target organs were compared with the existing ORISE values. METHODS After transmission scanning had been performed for measured attenuation, 525 MBq of (11)C-acetate were injected intravenously, and 5 sequential whole-body emission scans were obtained from the head to mid thighs. Regions of interest were drawn to encompass the entire activity in all visible organs at each time point. Time-activity data were fit in a least-squares sense to obtain residence times. Absorbed dose estimates were determined using MIRDOSE3.1 software. RESULTS The effective dose was 0.0049 mSv/MBq. The organs receiving the highest absorbed doses were the pancreas (0.017 mGy/MBq), bowel (0.011 mGy/MBq), kidneys (0.0092 mGy/MBq), and spleen (0.0092 mGy/MBq). No urinary excretion of tracer was measurable. CONCLUSION Using these new estimates for (11)C-acetate dosimetry, the maximum injected activity under Radioactive Drug Research Committee limits can be raised up to 5-fold over the limit imposed by the previous ORISE estimates. A higher injected activity would improve counting statistics and, it is hoped, overall image quality and tumor detection with whole-body (11)C-acetate PET.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Radiation Dosimetry of Whole-Body Dual-Tracer 18F-FDG and 11C-Acetate PET/CT for Hepatocellular Carcinoma.

UNLABELLED Combined whole-body dual-tracer ((18)F-FDG and (11)C-acetate) PET/CT is increasingly used for staging hepatocellular carcinoma, with only limited studies investigating the radiation dosimetry data of these scans. The aim of the study was to characterize the radiation dosimetry of combined whole-body dual-tracer PET/CT protocols. METHODS Consecutive adult patients with hepatocellula...

متن کامل

Evaluation of Radiation Exposure to Staff and Environment Dose from [18F]-FDG in PET/CT and Cyclotron Center using Thermoluminescent Dosimetry

Background: PET/CT imaging using [18F]-FDG is utilized in clinical oncology for tumor detecting, staging and responding to therapy procedures. Essential consideration must be taken for radiation staff due to high gamma radiation in PET/CT and cyclotron center. The aim of this study was to assess the staff exposure regarding whole body and organ dose and to evaluate environment dose in PET/CT an...

متن کامل

Radiation dosimetry and biodistribution of the TSPO ligand 11C-DPA-713 in humans.

UNLABELLED Whole-body PET/CT was used to characterize the radiation dosimetry of (11)C-DPA-713, a specific PET ligand for the assessment of translocator protein. METHODS Six healthy control subjects, 3 men and 3 women, underwent whole-body dynamic PET scans after bolus injection of (11)C-DPA-713. Subjects were scanned from head to mid thigh with 7 passes performed, with a total PET acquisitio...

متن کامل

Implementation of quadratic dose protocol for 18F-FDG whole-body PET imaging using a BGO-based PET/CT scanner, GE Discovery ST

Introduction: The ability of quadratic dose protocol to maintain a good quality image for an overweight and obese patient is well reported. However, a practical approach to the implementation of this protocol in whole-body imaging in Malaysia is currently lacking. Hence, the aim of this study is to derive the quadratic dose formula that suits our PET system. Metho...

متن کامل

Characterization of [11C]RO5013853, a novel PET tracer for the glycine transporter type 1 (GlyT1) in humans

We characterize a novel radioligand for the glycine transporter type 1 (GlyT1), [(11)C]RO5013853, in humans. Ten healthy male volunteers, 23-60 years of age, were enrolled in this PET study; seven subjects participated in the evaluation of test-retest reliability and three subjects in whole body dosimetry. Subjects were administered intravenous bolus injections of approximately 1100 MBq (30 mCi...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 45 7  شماره 

صفحات  -

تاریخ انتشار 2004