Development and initial clinical testing of "OPECT": an innovative device for fully intangible control of the intraoperative image-displaying monitor by the surgeon.
نویسندگان
چکیده
BACKGROUND During surgery, various images as well as other relevant visual information are usually shown upon request with the help of operating staff. However, the lack of direct control over the display may represent a source of stress for surgeons, particularly when fast decision making is needed. OBJECTIVE To present the development and initial clinical testing of an innovative device that enables surgeons to have direct intangible control of the intraoperative image-displaying monitor with standardized free-hand movements. METHODS The originally developed intangible interface named "OPECT" is based on the commercially available gaming controller KINECT (Microsoft) and dedicated action-recognizing algorithm. The device does not require any sensors or markers fixed on the hands. Testing was done during 30 neurosurgical operations. After each procedure, surgeons completed the 5-item questionnaire for evaluation of the system performance, scaling several parameters from 1 (bad) to 5 (excellent). RESULTS During surgical procedures, OPECT demonstrated high effectiveness and simplicity of use, excellent quality of visualized graphics, and precise recognition of the individual user profile. In all cases, the surgeons were well satisfied with performance of the device. The mean score value of answers to the questionnaire was 4.7 ± 0.2. CONCLUSION OPECT enables the surgeon to easily have intangible control of the intraoperative image monitor by using standardized free-hand movements. The system has promising potential to be applied for various kinds of distant manipulations with the displaying visual information during human activities.
منابع مشابه
A quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملDevelopment of system decision support tools for behavioral trends monitoring of machinery maintenance in a competitive environment
The article is centred on software system development for manufacturing company that produces polyethylene bags using mostly conventional machines in a competitive world where each business enterprise desires to stand tall. This is meant to assist in gaining market shares, taking maintenance and production decisions by the dynamism and flexibilities embedded in the package as customers’ demand ...
متن کاملACCURACY OF INTRAOPERATIVE FROZEN SECTION DIAGNOSIS AND TOUCH IMPRINT CYTOLOGY: STUDY ON 1000 CONSECUTIVE CASES
Frozen section and touch imprint cytology are important diagnostic procedures for surgeons during operation and must be accurate if the patient is to receive maximum benefit. To assess the accuracy of intraoperative pathologic consultation including frozen section and touch imprint cytology during a five year period (1995- 2000), a retrospective survey of 1000 consecutive cases of frozen s...
متن کاملطراحی و ساخت روبشگر فراصوتی جهت تهیه تصاویر روبش B (B-Scan) از قطعات صنعتی
The results of ultrasonic tests are usually displayed as A-scan signals. In an A-scan signal, reflections of ultrasonic wave form different reflectors are shown as sharp echoes on a time by amplitude display. Interpretation of these echoes can sometimes be quite difficult and usually requires knowledgeable and experienced specialists. There exist other methods of displaying the ultrasonic test...
متن کاملUse of a Digital Protractor and a Spirit Level to Determine the Intraoperative Anteversion of Femoral Component during Cemented Hip Hemiarthroplasty: a Prospective Clinical Trial
Background: Femoral stem anteversion during hip arthroplasty is generally estimated by eye intraoperatively and hasproven to be different from targeted values. This study aims to determine the accuracy of a novel technique using adigital protractor and a spirit level to improve surgeons’ estimation of stem anteversion.Methods: A prospective non-randomized study was conducted a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Neurosurgery
دوره 10 Suppl 1 شماره
صفحات -
تاریخ انتشار 2014