Assessment of a new transtelephonic portable spirometer.
نویسندگان
چکیده
BACKGROUND A new portable spirometer, the Spirophone, has been developed that records a subject's blow and can then transmit all the data by telephone to a receiving centre for analysis and comment. Tests of this device were undertaken to determine its accuracy and reliability. METHODS The performance of the Spirophone was tested using computer generated wave forms, by delivering blows from calibrated syringes at different flows, and by comparing subjects' blows with those recorded with a commercial spirometer. RESULTS Using computer generated wave forms all lung function indices were accurate to within 1% and blows delivered from calibrating syringes were accurate to within 5%. When subjects performed repeated forced vital capacity (FVC) manoeuvres there were no significant differences between lung function indices recorded with the Spirophone and with a commercial spirometer. With the Spirophone and commercial spirometer in series the FVC and forced expiratory volume in one second (FEV1) were within 5% of each other in nine out of 10 healthy subjects. CONCLUSION The Spirophone recorded maximal forced expiratory manoeuvres with acceptable accuracy, reliability, and reproducibility, and this system offers the ability to monitor a patient's lung function at a centre remote from the patient.
منابع مشابه
A comparison of a new transtelephonic portable spirometer with a laboratory spirometer.
The Spirophone is a new, portable transtelephonic spirometer which records the slow and the forced expiratory vital capacity tests. Data can be transmitted via the telephone to a remote receiving centre, where a volume-time curve and the flow-volume curve are displayed on screen in real time. The aim of this study was to compare the newly developed transtelephonic spirometer, with a laboratory ...
متن کاملEvaluating the use of a portable spirometer in a study of pediatric asthma.
STUDY OBJECTIVES Laboratory-based spirometry is the "gold standard" for the assessment of lung function, both in clinical and research protocols. These spirometers, however, are neither practical nor affordable for home-based monitoring or studies that collect data in multiple locations. Traditionally, peak flowmeters have been used, but they have important limitations. DESIGN Based on data f...
متن کاملValidation of the portable Air-Smart Spirometer
BACKGROUND The Air-Smart Spirometer is the first portable device accepted by the European Community (EC) that performs spirometric measurements by a turbine mechanism and displays the results on a smartphone or a tablet. METHODS In this multicenter, descriptive and cross-sectional prospective study carried out in 2 hospital centers, we compare FEV1, FVC, FEV1/FVC ratio measured with the Air S...
متن کاملUse of incentive spirometry in portable chest radiography.
PURPOSE The degree of lung inflation seen on a chest radiograph is dependent on the point during the patient's respiratory cycle at which the radiographer exposes the image receptor. Exposing the image receptor at the exact peak of inflation can be difficult because of the limited time available in which to capture the inspiratory pause. An incentive spirometer can indicate the moment of peak i...
متن کاملA Portable VolumejFlow Calibrating Syringe*
Two samples of a manual 3 L calibrating syringe which displays an electronically calculated FEF25-75% were evaluated to determine its suitability as a flow calibrator were evaluated. Room air was discharged into a manual spirometer system known to be accurate. The calibrator-determined values correlated very closely with the spirometer values over an FEF25-75 % range of 0.4 to 9 L/sec. The diff...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Thorax
دوره 51 4 شماره
صفحات -
تاریخ انتشار 1996