Contribution of different sources of signal variance to T2* and S0 maps in the human brain at rest: a 7T study

نویسندگان

  • M. Bianciardi
  • M. Fukunaga
  • P. van Gelderen
  • J. A. de Zwart
  • J. H. Duyn
چکیده

Purpose: Various noise sources affect BOLD fMRI time-courses and limit the benefits of high field fMRI. The aim of the present study was to investigate the contribution and the origin of non-thermal noise to fMRI signal fluctuations in the visual cortex at 7T during rest. The following noise sources were considered: 1) low frequency drifts; 2) effects related to the phase of respiration and cardiac cycles; effects due to fluctuations in the 3) respiratory flow rate and 4) cardiac rate; 5) thermal noise; 6) other sources, tentatively attributed to spontaneous neuronal activity. The variance explained by each noise source in BOLD-weighted single-echo, T2* and S0 images was then evaluated. Prediction: T2* signal fluctuations are expected for changes in intravoxel B0 gradients, e.g. due to fluctuations in hemodynamic parameters (oxygen consumption, blood flow, blood volume), and in phase with respiration cycles. S0 changes are related to fluctuations in real/apparent spin density (e.g. motion, B0 drifts) and in T1 (e.g. inflow, changes in blood volume). Methods: Six subjects (4m/2f, age 33±4) participated in the study (IRB approved protocol). Subjects were asked to rest in the MR scanner with their eyes closed. Multi-echo GE-EPI BOLD fMRI was performed at 7T (GE Medical Systems) using 32 receive-only coil-elements (NOVA Medical) and the following parameters: TR=2s, FA=75 ̊, N. slice=20, voxel-dim=2.5x2.5x2mm, slice-gap=2mm, SENSE-rate=3, N.scans=178. TEs=12/28.2/44.4ms were employed in odd scans (multi-echo set A)) and TEs=20.1/36.3/52.5ms in even scans (multi-echo set B)); the total acquisition length of a single EPI was 14.8ms. We also recorded the timing of physiological cycles (sampling rate = 250 Hz) by the use of a pulseoximeter and the respiratory bellows provided with the MR scanner. We defined a region of interest (ROI) in the visual cortex by the use of a functional localizer (retinotopy, N. scans = 245). Separately for multi-echo set A) and B), we extracted T2* and S0 (S0=S(TE=0)) by linear least square fitting of multi-echo data, assuming a mono-exponential signal decay. After standard image preprocessing, single-echo, T2* and S0 fMRI signals were converted to % signal change relative to their time average. Non-thermal noise sources 1)-4) were respectively modeled with: 1) three polynomial regressors; 2) eight RETROICOR regressors [1]; 3) two respiration volume per unit time (RVT) regressors [2] shifted at lag -8s and +8s (dual-lagged procedure, [3]); 4) two cardiac-rate regressors [4] shifted by lags of -4s and +8s [3]. The % fMRI signal variance explained (VE, %) by sources 1)-4) was computed as the R value adjusted for the degrees of freedom, multiplied by 100. VE explained by noise source 5) at the voxel level was measured as the ratio of the signal variance due to thermal noise divided by the total signal variance of each time series, multiplied by 100. The variance due to thermal noise was estimated in each voxel from an image with no radiofrequency excitation and was scaled by the square of the signal at a fixed time point in the same voxel at each echo time. Projection of this variance to T2* and S0 images was performed according to the rules of linear least square fitting. The VE associated with spontaneous fMRI activity was determined from the residual signal variance after accounting for noise sources 1)-5). We computed VE attributable to sources 1)-6) for secondecho, T2* and S0 signals both at the voxel level and averaged within the ROI in the visual cortex. Results: For each source, the explained variance in the visual cortex for second-echo, T2* and S0 signals of multi-echo set A) at the voxel and ROI level are shown in Fig. 1. Similar results were found for multi-echo set B). All non-thermal noise sources contributed to single-echo, T2* and S0 signal fluctuations. Low-frequency drifts and spontaneous activity were the major sources of non-thermal signal fluctuation. Both at the voxel and the ROI level, low-frequency drifts explained more variance in S0 than in T2* images (paired t-test, p<0.01). The opposite result was found for spontaneous activity (p<0.015) and changes in the respiratory flow rate (p<0.065); similar amount of variance in S0 and T2* images was explained by effects related to the phase of physiologic cycles and to fluctuations in the cardiac rate. Conclusions: The reflection of low-frequency drifts in both S0 and T2* indicates that they have both an instrumental and a physiological origin, in agreement with previous work [5]. Effects related to the phase of physiologic cycles (e.g. blood pulsatility, head motion, B0 changes in the head due to chest motion) and to fluctuations in the cardiac rate surprisingly contributed in similar amounts to T2* and S0 images. Fluctuations in respiratory flow rate showed a larger contribution in T2* than in S0 images, as expected considering that they may affect blood volume and flow. Finally, our results confirmed a TE dependence of spontaneous activity in the visual cortex, in line with previous work in the motor cortex [6]; nevertheless, residual spatially coherent spontaneous fluctuations were present in S0 images. References: [1] Glover et al., Magn Reson Med, 44:162-7, 2000. [2] Birn et al., Neuroimage, 31:1536-48, 2006. [3] Bianciardi et al., Magn Reson Imag, 27:1019-29, 2009. [4] Shmueli et al., Neuroimage, 38:306-320, 2007. [5] Yan et al., Magn Reson Med, 61:819-27, 2009. [6] Peltier and Noll, Neuroimage, 16:985-92, 2002.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Cognitive Activity Analysis of the Brain in Creative Design Thinking

The present study was aimed at analyzing cognitive activity of the brain during creative design thinking. This study was a causal-comparative study. The statistical population of the study was all students of Tabriz University in the period of 2016-17. At first, interested students were invited to participate in the research, and 30 of them were randomly selected and selected from delta, theta,...

متن کامل

Effect of Physiological noise on Thoraco-Lumbar spinal cord fMRI in 3T Magnetic field

Introduction: Functional MRI methods have been used to study sensorimotor processing in the brain and the Spinal cord. However, these techniques confront unwanted contributions to the measured signal from physiological fluctuations. For the spinal cord imaging, most of the challenges are consequences of cardiac and respiratory movement artifacts that are considered as signifi...

متن کامل

Extraction of Sensory part of Ulnar Nerve Signal Using Blind Source Separation Method

A recorded nerve signal via an electrode is composed of many evokes or action potentials, (originated from individual axons) which may be considered as different initial sources. Recovering these primitive sources in its turn may lead us to the anatomic originations of a nerve signal which will give us outstanding foresights in neural rehabilitations. Accordingly, clinical interests may be r...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

SWI: Probe for neuroradiologists

Susceptibility-weighted imaging (SWI) has continued to develop into a powerful clinical tool to visualize venous structures and iron in the brain and to study diverse pathologic conditions. It is a new art which evaluates and exploits the properties of blood, iron and other tissues. It is a magnitude or filtered phase images or combination of both, obtained with high-resolution 3D fully velocit...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2009