Expired carbon dioxide: a noninvasive monitor of cardiopulmonary resuscitation.
نویسندگان
چکیده
End-tidal CO2 concentration (ETCO2) may serve as a simple noninvasive measurement of the blood flow generated by precordial compression during cardiopulmonary resuscitation (CPR). In a mechanically ventilated porcine preparation of ventricular fibrillation, onset of fibrillation was associated with a rapid decrease in ETCO2 from 4.0 +/- 0.2% to less than 0.7 +/- 0.2%. With precordial compression, it increased to 1.9 +/- 0.3%. Animals that were successfully defibrillated after 12 min of CPR demonstrated an immediate increase in ETCO2. The ETCO2 increased from 1.9 +/- 0.3% to 4.9 +/- 0.3% over an interval of between 30 and 60 sec. These changes in ETCO2 were closely related to proportionally similar decreases and increases in cardiac output (CO), and a close correlation between ETCO2 and CO was demonstrated (r = .92). A similar highly significant correlation between ETCO2 and CO was also demonstrated during open-chest cardiac massage (r = .95). ETCO2 therefore serves as a noninvasive measure of pulmonary blood flow and therefore CO. In 17 successfully resuscitated animals. ETCO2 during precordial compression averaged 1.7 +/- 0.2%, whereas it was only 0.5 +/- 0.1% in five animals in whom resuscitation procedures were unsuccessful (p less than .001). Accordingly, ETCO2 prognosticates outcome during CPR and immediately identifies restoration of spontaneous circulation.
منابع مشابه
Partial pressure of end-tidal carbon dioxide successful predicts cardiopulmonary resuscitation in the field: a prospective observational study
INTRODUCTION Prognosis in patients suffering out-of-hospital cardiac arrest is poor. Higher survival rates have been observed only in patients with ventricular fibrillation who were fortunate enough to have basic and advanced life support initiated soon after cardiac arrest. An ability to predict cardiac arrest outcomes would be useful for resuscitation. Changes in expired end-tidal carbon diox...
متن کاملPartial pressure of end-tidal carbon dioxide predicts successful cardiopulmonary resuscitation in the field
Kolar and colleagues contribute an additional and important incentive for rescuers to utilize end-tidal carbon dioxide tensions as a routine monitor to guide management and decision-making during cardiopulmonary resuscitation. They conclude that below-threshold levels of 14 mmHg (1.5 kPa) measured after 20 minutes of cardiopulmonary resuscitation reliably predict that spontaneous circulation ca...
متن کاملCapnography In The Pediatric Emergency Department: Clinical Applications
Capnography, often referred to by emergency clinicians as end-tidal carbon dioxide monitoring, is a noninvasive method of measuring cardiopulmonary and metabolic parameters that can be utilized in many clinical applications. Growing evidence in the literature in support of the use of capnography has led to increased clinical use of this modality in many pediatric subspecialties. Understanding c...
متن کاملThe use of transcutaneous CO2 monitoring in cardiac arrest patients: a feasibility study
BACKGROUND Prediction of the return of spontaneous circulation (ROSC) in cardiac arrest patients is a parameter for deciding when to stop cardiopulmonary resuscitation (CPR) or to start extracorporeal CPR. We investigated the change in transcutaneous PCO2 (PtcCO2) in cardiac arrest patients. METHODS This study was carried out as a retrospective chart review. Patients with out-of-hospital card...
متن کاملActive decompression improves the haemodynamic state during cardiopulmonary resuscitation.
OBJECTIVE To examine whether use of the active compression-decompression device improves the haemodynamics of cardiopulmonary resuscitation compared with those of conventional cardiopulmonary resuscitation. DESIGN Prospective crossover study. SETTING The accident and emergency department of a university teaching hospital. PATIENTS 36 adult patients with non-traumatic, normothermic, out of...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Circulation
دوره 77 1 شماره
صفحات -
تاریخ انتشار 1988