Behaviour of FRP strengthened concrete columns under eccentric compression loading

نویسنده

  • Muhammad N. S Hadi
چکیده

This paper presents results of testing eccentrically loaded columns externally wrapped with two types of materials. Six cylindrical (205 mm diameter and 925 mm height) plain columns were cast and tested. Half of the columns were wrapped with GFRP and the other half with CFRP. All columns were tested by applying an axial load at 50 mm eccentricity. In each group (GFRP or CFRP wrapped) of columns, one column did not have any vertical straps, one had vertical straps made of one layer of wrapping material and one column had vertical straps made of three layers of materials. All columns were horizontally wrapped with three layers of material (GFRP or CFRP). A steel reinforced column was also cast and tested to serve as a reference column. Based on testing the columns it can be concluded that considerable gain in strength and ductility are gained when reinforcing the columns with CFRP (vertical straps and horizontally wrapped).

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Behavior of FRP-Confined Reactive Powder Concrete Columns under Eccentric Loading

Fiber reinforced Polymers (FRP) have widely used for the purposes of enhances strength and ductility of concrete columns. Proper design of such hybrid columns, however, requires a better recognition of the behavior of concrete columns confined with FRP. In this paper, the influence of FRP thickness, concrete compressive strength, and column size on the performance of eccentrically loaded reacti...

متن کامل

Behaviour of eccentric loading of FRP confined fibre steel reinforced concrete columns

This paper presents results of testing 16 specimens, 12 of which as columns under different eccentricities and four as beams under four point loading regime. All 16 specimens were circular in cross section and were made of reinforced concrete. Four specimens served as reference specimens and were just made of reinforced concrete. The next four specimens were wrapped with Carbon Fibre Reinforced...

متن کامل

The behaviour of FRP wrapped HSC columns under different eccentric loads

The majority of columns are subjected to a combination of an axial load and a bending moment in one or two directions. With a few exceptions, most of the research in the area of FRP wrapped columns have concentrated on the behaviour of concentrically loaded columns. This paper presents results of testing nine reinforced high strength concrete columns. The column specimens are circular in shape ...

متن کامل

Workshop Presentation Infrastructure Applications of Frp Composites Behaviour of High Strength Concrete Columns Reinforced with Gfrp Bars and Helices under Different Loading Conditions

The use of Glass Fibre Reinforced Polymer (GFRP) bars is considered an alternative option in reinforcing concrete structures instead of conventional steel bars especially in harsh severe environments, due to their mechanical properties and physical characteristics. GFRP bars offer many advantages over steel counterparts such as corrosion resistance, high tensile strength, low weight and electro...