A dosimetric intercomparison of kilovoltage X-rays, megavoltage photons and electrons in the Republic of Ireland.

نویسندگان

  • A Nisbet
  • D I Thwaites
  • M E Sheridan
چکیده

BACKGROUND AND PURPOSE A comprehensive dosimetry intercomparison has been carried out involving all the radiotherapy centres, all external beam modalities and every radiotherapy treatment unit in the Republic of Ireland. MATERIALS AND METHODS Reference point measurements were made for all megavoltage photon beams. Doses were also investigated in planned three-field distributions. One of these was in a homogeneous epoxy resin solid water phantom, whilst the second included a lung equivalent insert. The intercomparison was also carried out for three electron energies in each centre. The position of the depth of maximum dose for a standard field size was independently determined, as was the beam energy and a subsequent beam calibration was made. In addition, a kilovoltage X-ray intercomparison was carried out on every kilovoltage quality. RESULTS For 13 megavoltage photon beams a mean ratio of intercomparison measured dose to locally measured dose of 1.002 was obtained (standard deviation 1.2%). For 12 electron beam measurements a mean ratio of intercomparison measured dose to locally measured dose of 1.018 was obtained (standard deviation 0.8%). For four kilovoltage beams a mean ratio of intercomparison measured dose to locally measured dose of 0.997 was obtained (standard deviation 1.9%). CONCLUSIONS The intercomparison has given confidence in the basis of clinical delivery of radiation dose in radiotherapy treatment and in the consistency (precision) of dosimetry between different centres within the Republic of Ireland. In addition, it has established a methodology for subsequent ongoing routine radiotherapy dosimetry audit and a baseline set of results to act as an initial reference point.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison of kilovoltage x-ray and electron beam dose distributions for radiotherapy of the sternum.

The dose distributions for a patient with cancer involving the sternum were calculated for both a kilovoltage x-ray beam and a megavoltage electron beam. The minimum target dose and dose uniformity over the target volume were significantly better using electrons (90%-101%) than kilovoltage x-rays (68%-119%). The calculated lung dose and integral patient dose were also less for electrons than ki...

متن کامل

Monte Carlo calculation of shielding properties of newly developed heavy concretes for megavoltage photon beam spectra used in radiation therapy

Introduction: Globally, the need for radiotherapy as a part of cancer management increases every year. Thus, the shielding for megavoltage radiotherapy rooms is of great importance. Materials and Methods: In the present study, 14 types of developed high-density concrete with densities ranging from 2.45 to 5.11 were simulated by using Monte Carlo method. The linear attenuation coefficient and t...

متن کامل

Studying Effects of Gold Nanoparticle on Dose Enhancement in Megavoltage Radiation

Background: Gold nanoparticles are emerging as promising agents for cancer therapy and are being investigated as drug carriers, photothermal agents, contrast agents and radiosensitisers.Objective: The aim of this study is to understand characteristics of secondary electrons generated from interaction of gold nanoparticles GNPs with x-rays as a function of nanoparticle size and beam energy and ...

متن کامل

Study of Dosimetric Properties of Flattening Filter Free Photon Beam Passing through Cadmium Free Compensator Alloy

Background: This study aims to investigate radiation beam geometry of Cyberknife beam and change in dosimetric characteristics of six megavoltage (6MV) flattening filter free (FFF) beam after passing through high density cadmium free compensator alloy.Material and Methods: In this experimental study, changes in FFF beam dosimetric characteristics after passing through compensator alloy wa...

متن کامل

The energy dependence and dose response of a commercial optically stimulated luminescent detector for kilovoltage photon, megavoltage photon, and electron, proton, and carbon beams.

Optically stimulated luminescent detectors, which are widely used in radiation protection, offer a number of potential advantages for application in radiation therapy dosimetry. Their introduction into this field has been somewhat hampered by the lack of information on their radiation response in megavoltage beams. Here the response of a commercially available optically stimulated luminescent d...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology

دوره 48 1  شماره 

صفحات  -

تاریخ انتشار 1998