VCO2 calorimetry: stop tossing stones, it’s time for building!

نویسندگان

  • Elisabeth De Waele
  • Patrick M. Honoré
  • Herbert D. Spapen
چکیده

We followed with interest the discussion [1, 2] fueled by the study of Stapel et al. [3] who reported fairly accurate assessment of energy expenditure (EE) in critically ill patients based on ventilator-derived carbon dioxide production (VCO2). The proposed technique is elegant and valid but has inherent limitations. It is applicable in patients who are in one way or another ventilator-dependent but not in spontaneously breathing yet oxygen-dependent subjects. We concur that VO2 is the most relevant variable for EE measurement. However, the most accurate and precise estimation of EE in a critically ill population can only be obtained by sampling of inspired and expired oxygen/ carbon dioxide concentrations and measuring expired gas flow. This is the core task of indirect calorimetry [4]. Initiative has been undertaken to develop a ‘full option’, easy-to-use, accurate, and affordable indirect calorimeter. The project is supported by the European Society of Intensive Care Medicine and the European Society of Parenteral and Enteral Nutrition [5] and has actually reached Technology Readiness Level. It is probably only a matter of time before such a device will render all current mathematical uproar obsolete.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Energy expenditure in critically ill patients estimated by population-based equations, indirect calorimetry and CO2-based indirect calorimetry

BACKGROUND Indirect calorimetry (IC) is the reference method for measurement of energy expenditure (EE) in mechanically ventilated critically ill patients. When IC is unavailable, EE can be calculated by predictive equations or by VCO2-based calorimetry. This study compares the bias, quality and accuracy of these methods. METHODS EE was determined by IC over a 30-min period in patients from a...

متن کامل

VCO2 calorimetry is a convenient method for improved assessment of energy expenditure in the intensive care unit

In their interesting article, Stapel et al. [1] suggested the use of carbon dioxide production (VCO2) calorimetry with energy expenditure (EE; kcal/day), calculated as 8.19 × VCO2 (ml/min), where VCO2 is provided by the built-in capnometer of the mechanical ventilator. This calculation on average overestimated EE by 7.7 % compared to indirect calorimetry (IC) with a standard deviation (SD) of ±...

متن کامل

VO2 and VCO2 variabilities through indirect calorimetry instrumentation

The aim of this paper is to understand how to measure the VO2 and VCO2 variabilities in indirect calorimetry (IC) since we believe they can explain the high variation in the resting energy expenditure (REE) estimation. We propose that variabilities should be separately measured from the VO2 and VCO2 averages to understand technological differences among metabolic monitors when they estimate the...

متن کامل

A Cross-sectional Study of Resting Cardio-respiratory and Metabolic Changes in Pregnant Women

[Purpose] We examined cardiorespiratory and metabolic changes across the 1st (G1), 2nd (G2) and 3rd (G3) trimesters in pregnant women. [Subjects and Methods] Forty-two healthy, active, non-smoking, pregnant women participated in this study. They were divided into G1, G2 and G3 groups depending on their mean gestational ages at the time of testing which were 10.5 ±2.9, 19.2 ±3.4, and 33.3 ±2.4 w...

متن کامل

بررسی پرتوهای گاما در سنگ‌های ساختمانی موجود در شهر کرمان، سال 1392

Abstract Introduction:Some of the building stones have radioactive elements such as uranium and thorium and since people spend averagely 80 % of their time within the buildings, it increases the possibility of sunshine exposure. The aim of this study was to evaluate the dosimetry of building stones in Kerman in 2013 to determine the radioactivity of them. Methods: From the salestones of Kerman,...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2016