Facing the noise: addressing the endemic variability in D(LCO) testing.
نویسنده
چکیده
Single-breath diffusing capacity of the lung for carbon monoxide (D(LCO)) is a common pulmonary function test that measures the ability of the lung to exchange gas across the alveolar-capillary interface. D(LCO) testing is used to narrow the differential diagnosis of obstructive and restrictive lung disease, to aid in disability and transplant assessment, and to monitor medication toxicity. The variability in the measurement limits the utility of the test. Variability is attributable to differences in equipment, testing conditions, patient factors, and reference equations. Laboratories can minimize variability by ensuring that equipment meets recommended standards, implementing effective quality control programs, standardizing testing conditions and testing procedures, and accounting for pertinent patient characteristics.
منابع مشابه
Single-breath diffusing capacity for carbon monoxide instrument accuracy across 3 health systems.
BACKGROUND Measuring diffusing capacity of the lung for carbon monoxide (DLCO) is complex and associated with wide intra- and inter-laboratory variability. Increased D(LCO) variability may have important clinical consequences. The objective of the study was to assess instrument performance across hospital pulmonary function testing laboratories using a D(LCO) simulator that produces precise and...
متن کاملMulti-wavelength pulse oximeter is not suitable for adjusting D(LCO) measurements.
BACKGROUND Diffusing capacity of the lung for carbon monoxide (D(LCO)) can be affected by abnormal hemoglobin (Hb) or carboxyhemoglobin (COHb) levels. Predicted D(LCO) can be adjusted to reflect abnormal Hb or COHb levels. Until recently, blood sampling was required to determine Hb and COHb levels, but a new pulse oximeter, the Masimo RAD-57, can measure Hb and COHb noninvasively. We hypothesiz...
متن کاملNoninvasive measurement of carboxyhemoglobin levels for adjustment of diffusion capacity measured during pulmonary function testing.
BACKGROUND The diffusing capacity of the lungs for carbon monoxide (D(LCO)) is commonly measured during pulmonary function testing (PFT). Although adjustment of the measured D(LCO) for an elevated baseline carboxyhemoglobin level is recommended, carboxyhemoglobin is not routinely measured, which may reduce the accuracy of D(LCO) measurements. We sought to assess the utility of routine carboxyhe...
متن کاملDiffusing capacity: how to get it right.
The carbon monoxide diffusing capacity test (D(LCO)) is a commonly performed pulmonary function test that requires technical expertise and attention to detail to get acceptable results. With the advent of automated devices and powerful computer programs, D(LCO) measurement has rapidly gained wide clinical acceptance. But there are many subtle aspects to performing the test that can diminish its...
متن کاملPredicted postoperative product and diffusion heterogeneity index in the evaluation of candidates for lung resection.
OBJECTIVES The primary objective of this retrospective study was to evaluate whether abnormal predicted postoperative variables and predicted postoperative product are useful in predicting postoperative complications. The secondary objective was to assess whether an abnormal diffusion heterogeneity index is associated with increased postoperative complications. METHODS In this retrospective s...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Respiratory care
دوره 57 1 شماره