Dynamic fetal cardiovascular magnetic resonance imaging using Doppler ultrasound gating

نویسندگان

  • Fabian Kording
  • Jin Yamamura
  • Manuela Tavares de Sousa
  • Christian Ruprecht
  • Erik Hedström
  • Anthony H Aletras
  • P Ellen Grant
  • Andrew J Powell
  • Kai Fehrs
  • Gerhard Adam
  • Hendrik Kooijman
  • Bjoern P Schoennagel
چکیده

BACKGROUND Fetal cardiovascular magnetic resonance (CMR) imaging may provide a valuable adjunct to fetal echocardiography in the evaluation of congenital cardiovascular pathologies. However, dynamic fetal CMR is difficult due to the lack of direct in-utero cardiac gating. The aim of this study was to investigate the effectiveness of a newly developed Doppler ultrasound (DUS) device in humans for fetal CMR gating. METHODS Fifteen fetuses (gestational age 30-39 weeks) were examined using 1.5 T CMR scanners at three different imaging sites. A newly developed CMR-compatible DUS device was used to generate gating signals from fetal cardiac motion. Gated dynamic balanced steady-state free precession images were acquired in 4-chamber and short-axis cardiac views. Gating signals during data acquisition were analyzed with respect to trigger variability and sensitivity. Image quality was assessed by measuring endocardial blurring (EB) and by image evaluation using a 4-point scale. Left ventricular (LV) volumetry was performed using the single-plane ellipsoid model. RESULTS Gating signals from the fetal heart were detected with a variability of 26 ± 22 ms and a sensitivity of trigger detection of 96 ± 4%. EB was 2.9 ± 0.6 pixels (4-chamber) and 2.5 ± 0.1 pixels (short axis). Image quality scores were 3.6 ± 0.6 (overall), 3.4 ± 0.7 (mitral valve), 3.4 ± 0.7 (foramen ovale), 3.6 ± 0.7 (atrial septum), 3.7 ± 0.5 (papillary muscles), 3.8 ± 0.4 (differentiation myocardium/lumen), 3.7 ± 0.5 (differentiation myocardium/lung), and 3.9 ± 0.4 (systolic myocardial thickening). Inter-observer agreement for the scores was moderate to very good (kappa 0.57-0.84) for all structures. LV volumetry revealed mean values of 2.8 ± 1.2 ml (end-diastolic volume), 0.9 ± 0.4 ml (end systolic volume), 1.9 ± 0.8 ml (stroke volume), and 69.1 ± 8.4% (ejection fraction). CONCLUSION High-quality dynamic fetal CMR was successfully performed using a newly developed DUS device for direct fetal cardiac gating. This technique has the potential to improve the utility of fetal CMR in the evaluation of congenital pathologies.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BRCA Associated Tumors—Not Just Breast and Ovarian Cancer

Several attempts have been made in the past at imaging the fetus at 3T as part of the continuous search for increased image signal and better anatomic delineation of the developing fetus. Until now, imaging of the fetus at 3T has been disappointing, with numerous artifacts impeding image analysis. Improved technology now allows imaging of the fetus at greater magnetic strength, while still enco...

متن کامل

Evaluation of tissue doppler echocardiography and T2* magnetic resonance imaging in iron load of patients with thalassemia major

Background: Iron-mediated cardiomyopathy is the main complication of thalassemia major (TM) patients. Therefore, there is an important clinical need in the early diagnosis and risk stratification of patients. The aim of this study was to evaluate the efficacy of tissue doppler imaging (TDI) to study cardiac iron overload in patients with TM using T2* magnetic resonance (MR) as the gold-standard...

متن کامل

Dynamic imaging of the fetal heart using metric optimized gating.

PURPOSE Advances in fetal cardiovascular magnetic resonance imaging have been limited by the absence of a reliable cardiac gating signal. The purpose of this work was to develop and validate metric-optimized gating (MOG) for cine imaging of the fetal heart. THEORY AND METHODS Cine MR and electrocardiogram data were acquired in healthy adult volunteers for validation of the MOG method. Compari...

متن کامل

Clinically low‐risk prostate cancer: evaluation with transrectal doppler ultrasound and functional magnetic resonance imaging

OBJECTIVES To evaluate transrectal ultrasound, amplitude Doppler ultrasound, conventional T2-weighted magnetic resonance imaging, spectroscopy and dynamic contrast-enhanced magnetic resonance imaging in localizing and locally staging low-risk prostate cancer. INTRODUCTION Prostate cancer has been diagnosed at earlier stages and the most accepted classification for low-risk prostate cancer is ...

متن کامل

The Effect of Magnetic Resonance Imaging on Fetal Heart Rate

Introduction Safety is one of the main issues surrounding any imaging modality in obstetrics. The use of Doppler ultrasound to detect gross changes in fetal heart rate (FHR) is an accurate and objective method of assessing fetal distress or well-being. Magnetic Resonance Imaging (MRI) has previously been applied to the accurate estimation of fetal weight, organ size and in the measurement of pl...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 20  شماره 

صفحات  -

تاریخ انتشار 2018