Image restoration for confocal microscopy: improving the limits of deconvolution, with application to the visualization of the mammalian hearing organ.

نویسندگان

  • J Boutet de Monvel
  • S Le Calvez
  • M Ulfendahl
چکیده

Deconvolution algorithms have proven very effective in conventional (wide-field) fluorescence microscopy. Their application to confocal microscopy is hampered, in biological experiments, by the presence of important levels of noise in the images and by the lack of a precise knowledge of the point spread function (PSF) of the system. We investigate the application of wavelet-based processing tools to deal with these problems, in particular wavelet denoising methods, which turn out to be very effective in application to three-dimensional confocal images. When used in combination with more classical deconvolution algorithms, these methods provide a robust and efficient restoration scheme allowing one to deal with difficult imaging conditions. To make our approach applicable in practical situations, we measured the PSF of a Biorad-MRC1024 confocal microscope under a large set of imaging conditions, including in situ acquisitions. As a specific biological application, we present several examples of restorations of three-dimensional confocal images acquired inside an intact preparation of the hearing organ. We also provide a quantitative assessment of the gain in quality achieved by wavelet-aided restorations over classical deconvolution schemes, based on a set of numerical experiments that we performed with test images.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

PSO-Optimized Blind Image Deconvolution for Improved Detectability in Poor Visual Conditions

Abstract: Image restoration is a critical step in many vision applications. Due to the poor quality of Passive Millimeter Wave (PMMW) images, especially in marine and underwater environment, developing strong algorithms for the restoration of these images is of primary importance. In addition, little information about image degradation process, which is referred to as Point Spread Function (PSF...

متن کامل

Restoration methods for biomedical images in confocal microscopy

This thesis introduces new solutions to the problem of image restoration in biomedical fields. The confocal microscope is a relatively new imaging technique that is emerging as a standard tool in biomedical studies. This technique is capable of collecting a series of 2D images of single sections inside a specimen to form a 3D image of the object. Moreover, the use of laser light increases the r...

متن کامل

The analysis of nuclear tracks with confocal microscopy and image restoration

To measure radiation damage of particles with high energy and charge in space, radiosensitive plastics are used, in which particles leave damage tracks where they pass. These tracks are then etched, after which they have a typical cone shape. The geometrical parameters of these cones give information about energy and charge of the particles. To measure these parameters, the tracks are recorded ...

متن کامل

4Pi confocal microscopy with alternate interference.

We introduce 4Pi confocal microscopy with destructive interference of converging waves. Linear lobe deconvolution as well as nonlinear restoration of 4Pi confocal raw data with their point-spread functions (PSF's) leads to almost-identical images, irrespective of whether the 4Pi confocal PSF relies on constructive or destructive interference. Three-dimensional imaging of microtubules of a mouse...

متن کامل

Comparison of 3D microscopy methods by imaging a well characterized test object

We used a 10-μm-diameter fluorescent bead as a test object for 3D microscopy, and independently determined its structure by examining 1-μm-thick physical sections of the bead. Images of the full bead on different 3D microscopes revealed a number of aberrations and distortions. Images also showed evidence for absorption and/or scattering on all confocal and wide-field microscopes tested, but not...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Biophysical journal

دوره 80 5  شماره 

صفحات  -

تاریخ انتشار 2001