Lead Extraction of Cardiac Rhythm Devices: A Report of a Single-Center Experience

نویسندگان

  • Ana Isabel Azevedo
  • João Primo
  • Helena Gonçalves
  • Marco Oliveira
  • Luís Adão
  • Elisabeth Santos
  • José Ribeiro
  • Marlene Fonseca
  • Adelaide V. Dias
  • Luís Vouga
  • Vasco Gama Ribeiro
چکیده

INTRODUCTION AND OBJECTIVES The rate of implanted cardiac electronic devices is increasing as is the need to manage long-term complications. Lead removal is becoming an effective approach to treat such complications. We present our experience in lead removal using different approaches, analyzing the predictors of the use of mechanical extractors/surgical removal. METHODS Retrospective analysis of lead extractions in a series of 76 consecutive patients (mean age 70.4 ± 13.8 years, 73.7% men) between January 2009 and November 2015. RESULTS One hundred thirty-five leads from permanent pacemakers (single chamber 19.7%; dual-chamber 61.8%), implantable cardioverter defibrillators (5.3%), and cardiac resynchronization devices (CRT-P 2.6%; CRT-D 7.9%) were removed, 72.5 ± 73.2 months after implantation. A total of 45.9% were ventricular leads, 40.0% atrial leads, 8.9% defibrillator leads, and 5.2% leads in the coronary sinus; 64.4% had passive fixation. The most common indications for removal were pocket infection (77.8%), infective endocarditis (9.6%), and lead dislodgement (3.7%). A total of 76.3% of the leads were explanted, 20.0% were extracted, and 3.7% were surgically removed. Extraction of the entire lead was achieved in 96.3% of the procedures. After logistic regression (age adjusted), time since implantation was the sole predictor of the need of mechanical extractors/surgical removal. All patients were discharged without major complications. There were no deaths at 30 days. CONCLUSION Our experience in lead removal was effective and safe. Performing these procedures by experienced electrophysiologists with an adequate cardiothoracic surgery team on standby to cope with any complications is required. Referral of high-risk patients to a high-volume center is recommended to optimize clinical success and minimize procedural complications.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Transvenous extraction of cardiac rhythm device leads: a report of the experience from a single referral centre in Greece.

INTRODUCTION As rates of implanted cardiac electronic devices continue to rise, lead extraction procedures are crucial for the management of complications. The optimal method for such procedures has been constantly debated. We sought to review our experience of lead extraction using a conventional technique. METHODS This was a retrospective study of lead extraction procedures in a major refer...

متن کامل

The Improvement of the Atrial Flutter Rhythm upon the Removal of the Infected Permanent Pacemaker Lead

Pacemaker infection has multiple risk factors. Its presentation is most often similar to infected endocarditis and the diagnosis is made through studying blood cultures. Transesophageal echocardiography can confirm the diagnosis. The most common microorganisms are staphylococcus speciesis. As a matter of fact, complete pacemaker removal appears to be the only definite treatment. We presented a ...

متن کامل

Early Clinical Outcomes and Mortality of Coronary Endarterectomy in the Left Anterior Descending Artery: A Single-Center Experience

Introduction: Although coronary endarterectomy is not an ideal procedure, it is the only available option for cardiac surgeons in some patients with diffuse coronary artery disease. Based on the majority of conducted studies, the results of coronary endarterectomy (including survival, graft patency, and recurrence of the symptoms of myocardial ischemia) are less prevalent than standard coronary...

متن کامل

Cardiac Myxoma, a Rare But Most Common Encountered Cardiac Tumor: A Single Center Experience

Introduction: Cardiac myxoma is a benign and rare tumor, which can present with a grim phenomenon if the presentation is late or the diagnosis and surgery are delayed. The purpose of this study was to share our institutional experience of cardiac myxoma. Material and Methods: This retrospective study was conducted to evaluate patients undergoing procedures at a single tertiary care centre for t...

متن کامل

Endocardial Lead Extraction in the Polish Registry – clinical practice versus current Heart Rhythm Society consensus

INTRODUCTION Over the last 10 years, there has been an increasing number of patients with pacemaker (PM) and cardioverter-defibrillator (ICD). This study is a retrospective analysis of indications for endocardial pacemaker and ICD lead extractions between 2003 and 2009 based on the experience of three Polish Referral Lead Extraction Centers. MATERIAL AND METHODS Since 2003, the authors have c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2017