3D T1-weighted self-gated cardiac MRI for assessing myocardial infarction in mouse models
نویسندگان
چکیده
Background Mouse models with mycardial infarction (MI) have been intensively used to investigate the cardiac remodeling and functional change [1,2]. MRI with ECG triggering and respiratory gating (or breath-holding) is commonly used to assess MI due to its noninvasive nature. However, the manipulations of external ECG triggering and respiratory gating are cumbersome due to the small size of mouse. To address this issue, a 3D self-gating (SG) MR technique with stack-of-stars sampling trajectories was proposed for retrospectively cardiac and respiratory-gated MI imaging in mouse models [3]. Methods: Technical Design: MR data was acquired by a T1-weighted GRE sequence with stack-of-stars sampling trajectories and a partition-first golden-angle reordering (Figure 1a). The centers of k-space lines acquired at the same angle from individual partitions were aggregated and used as an SG time point. The periodic respiratory and cardiac motions were then detected through an iterative filtering process on the SG time series according to the cardiac rate of 300~500 per minute and respiration rate of 70~110 per minute. After resorting the imaging data into appropriate cardiac and respiratory phases, motion-artifact-free were finally reconstructed. Experiments: The SG technique was preliminarily validated on 5 mice with MI induction and all MR scans were performed on a 3T scanner (Siemens Tim Trio, Germany) with a customized 4-channal mouse coil. Typical imaging parameters for the ungated GRE sequence included: flip angle = 18°, TR = 4.2 ms, TE = 2.4 ms, spatial resolution = 0.6 × 0.6 × 1.5 mm, bandwidth = 620 Hz/Pixel, partition number = 12, and a total number of 3200 projections were continuously collected, corresponding to a fixed scan time of 3 min. An amount of 0.5 ml gadolinium contrast agent with concentration of 0.5 mmol/ml (Consun Pharmaceutical Group Limited, GuangZhou, China) was injected to enhance the MI. The mice were sacrificed immediately after MRI for histological analysis and comparison to the MR results.
منابع مشابه
Three-dimensional self-gated cardiac MR imaging for the evaluation of myocardial infarction in mouse model on a 3T clinical MR system
PURPOSE To develop and assess a three-dimensional (3D) self-gated technique for the evaluation of myocardial infarction (MI) in mouse model without the use of external electrocardiogram (ECG) trigger and respiratory motion sensor on a 3T clinical MR system. METHODS A 3D T1-weighted GRE sequence with stack-of-stars sampling trajectories was developed and performed on six mice with MIs that wer...
متن کاملFast and robust 3D T1 mapping using spiral gradient shape and continuous radio-frequency excitation at 7 T : Application on cardiac Manganese Enhanced (MEMRI) MRI in mice
Background Mapping the longitudinal relaxation time (T1) is a promising quantitative tool for the detection of myocardial pathologies either in mouse or human. T1 maps are usually obtained in 2D in order to reduce the total scan time. However, to diagnose myocardial infarction it might be useful to obtain the T1 maps in three dimensions (3D) which require a long acquisition time. In this projec...
متن کاملQuantitative evaluation of ischemic myocardial scar tissue by unenhanced T1 mapping using 3.0 Tesla MR scanner.
PURPOSE We aimed to use a noninvasive method for quantifying T1 values of chronic myocardial infarction scar by cardiac magnetic resonance imaging (MRI), and determine its diagnostic performance. MATERIALS AND METHODS We performed cardiac MRI on 29 consecutive patients with known coronary artery disease (CAD) on 3.0 Tesla MRI scanner. An unenhanced T1 mapping technique was used to calculate T...
متن کاملMONITORING DYNAMIC CALCIUM HOMEOSTASIS ALTERATIONS BY T1-WEIGHTED AND T1-MAPPING CARDIAC MANGANESE- ENHANCED MRI (MEMRI) IN A MURINE MYOCARDIAL INFARCTION MODEL A Thesis
متن کامل
Temporal Cardiac Manganese-Enhanced MRI with T1-mapping in Mice following Myocardial Infarction
8d 29d Figure 1: Example of short axis mouse heart T1-maps at three different time points (2 days, 8 days and 29 days) post-surgery. The upper is for Sham operated and the ROI regions delineated at LV Wall; the lower is for MI and the ROI regions delineated at MI injury site, adjacent zones and remote zone. Temporal Cardiac Manganese-Enhanced MRI with T1-mapping in Mice following Myocardial Inf...