Mechanical strength of arthroscopic rotator cuff repair techniques: an in vitro study.
نویسندگان
چکیده
BACKGROUND Retears after rotator cuff repairs occur relatively frequently and may compromise the functional result. The goal of this study was to analyze the mechanical properties following arthroscopic techniques for rotator cuff repair and to evaluate possible alternative techniques. METHODS In the first part, five different bone anchors (the Revo screw; Mitek Rotator Cuff anchor, 5.0-mm Statak, PANALOK RC absorbable anchor, and 5.0-mm Bio-Statak) were tested in vitro under cyclic loading on five pairs of cadaveric shoulders. Then five types of arthroscopic tendon suturing instruments were tested on rotator cuff tendons. Finally, the arthroscopically performed mattress and modified Mason-Allen stitches, fixed with either the Revo screw or the Bio-Statak, were evaluated on ten pairs of human cadaveric shoulders. RESULTS The holding strengths of the various anchors were similar, ranging from 130 to 180 N, and approximated the holding strength of knotted number-2 suture materials. The fixation of the tested anchors yielded comparable values of stiffness except for one anchor, which showed significantly greater subsidence under cyclic load (p = 0.003). All tested, commercially available arthroscopic suturing devices were unsuitable for performing a modified Mason-Allen stitch on normal supraspinatus tendons. Modification of a commercially available suture punch with a longer needle allowed us to consistently perform a modified Mason-Allen stitch. The modified Mason-Allen stitch, which has shown favorable mechanical properties in open repairs of the rotator cuff, was not found to be stronger than the mattress stitch when performed arthroscopically and used with bone anchors. When the modified Mason-Allen stitch was fixed to one anchor, it was even weaker than a mattress stitch repaired with another anchor (168 versus 228 N). Unequal loading of the two suture branches due to the more rigid modified Mason-Allen stitch may be the reason for this difference. CONCLUSIONS Arthroscopic techniques for rotator cuff repair with use of the mattress stitch and bone anchors allow for a relatively solid fixation. The holding strength is not improved with use of the modified Mason-Allen stitch. Although a direct comparison with previous in vitro studies is not possible, the holding strength of open fixation techniques seems to be stronger. If rotator cuffs are subjected to high postoperative loading, open repair might be preferred to reduce the risk of a retear, until stronger arthroscopic fixation techniques are developed.
منابع مشابه
Short term results of arthroscopic repair of subscapularis tendon tear
Abstract Background: Despite being the largest rotator cuff tendon of the shoulder, the function and clinical relevance of subscapularis pathology has been largely ignored in the literature. Although many studies have focused on subscapularis tears recently, majority of them reported techniques for open repair. The advent of arthroscopy and arthroscopic repair techniques has opened ...
متن کاملPreliminary Results of a Consecutive Series of Large & Massive Rotator Cuff Tears Treated with Arthroscopic Rotator Cuff Repairs Augmented with Extracellular Matrix
Background: Recurrence rate of rotator cuff tears is still high despite the improvements of surgical techniques, materials used and a better knowledge of the healing process of the rotator cuff tendons. Large to massive rotator cuff tears are particularly associated with a high failure rate, especially in elderly. Augmentation of rotator cuff repairs with extracellular matrix or synthetic patc...
متن کاملArthroscopic repair of complete tear of rotator cuff
Abstract Background: Rotator cuff tear is one of the most common causes of shoulder complaints in the elderly. Based on the severity and patient's condition, a variety of methods applies to manage the tear and surgery is an important method, which could be done by open or arthroscopic technique. The current study aimed to investigate and report short-term results of arthroscopic repair of...
متن کاملArthroscopic Rotator Cuff Repair: A Biomechanical Comparison of Single Row and Suture-Bridge Tendon Repair Constructs
INTRODUCTION: Rotator cuff tears are a very common source of pain and loss of function of the shoulder. As arthroscopic instrumentation and repair techniques have evolved, many studies have demonstrated success in repairing rotator cuff tears using these arthroscopic techniques alone compared with an open repair method. Despite these successful clinical outcomes, both open and arthroscopic rota...
متن کاملArthroscopic rotator cuff repairs: an anatomic and biomechanical rationale for different suture-anchor repair configurations.
The goal of rotator cuff repairs is to achieve high initial fixation strength, minimize gap formation, maintain mechanical stability under cyclic loading, and optimize the biology of the tendon-bone interface until the cuff heals biologically to the bone. We have seen an evolution in our approaches to fixing rotator cuff tears from open to mini-open to all arthroscopic. In our arthroscopic tech...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. American volume
دوره 84-A 12 شماره
صفحات -
تاریخ انتشار 2002