Flap irritation phenomenon (FLIP): etiology of chronic tenosynovitis after finger pulley rupture.

نویسندگان

  • Isabelle Schöffl
  • Thomas Baier
  • Volker Schöffl
چکیده

After a pulley rupture, most climbers regain the full function of their previously uninjured fingers. However, in some cases of pulley rupture, a persistent inflammation of the tendon sheath is observed. In this study, 16 cadaver fingers were loaded until pulley rupture and then studied for the rupturing mechanism. In addition, two patients with this pathology were investigated using ultrasound and MRI, and received surgery. In 13 fingers, a rupture of one or several pulleys occurred and almost always at the medial or lateral insertion. In one finger, a capsizing of the pulley underneath the intact tendon sheath was observed, leading to an avulsion between tendon and tendon sheath. A similar pathology was observed in the ultrasound imaging, in MRI, and during surgery in two patients with prolonged recovery after minor pulley rupture. In cases of prolonged tenosynovitis after minor pulley rupture, a capsizing of the pulley stump is probably the cause for constant friction leading to inflammation. In those cases, a surgical removal of the remaining pulley stump and sometimes a pulley repair may be necessary.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Subclinical Partial Attritional Rupture of the Flexor Digitorum Profundus as an Etiology of Atraumatic Trigger Finger

BACKGROUND Trigger finger is a relatively common clinical entity. The etiology is most often attributable to stenosing tenosynovitis though traumatic cases have been described. When trigger finger is associated with an underlying flexor tendon rupture, previous cases have reported a clear association with overt laceration or previous trauma. METHODS We present the case of a 23-year-old male a...

متن کامل

Reverse Trigger Finger: Does it exist? A Case Report

Trigger finger is a common condition, occurs primarily at the A1 pulley and tenosynovitis is the usual cause. However, although rare, triggering of the flexor tendon can occur in other areas. We present previously unreported condition in adult: triggering at the distal end of A2 pulley, which was caused by nodular thickening of the flexor digitorium profondus tendon with degeneration. A 79-year...

متن کامل

Trigger digits: principles, management, and complications.

Stenosing tenosynovitis, or trigger finger, is an entity seen commonly by hand surgeons. This problem generally is caused by a size mismatch between the flexor tendon and the first annular (A-1) pulley. Conservative management includes splinting, corticosteroid injection, and other adjuvant modalities. Surgical treatment consists of release of the A-1 pulley by open or percutaneous techniques. ...

متن کامل

Impact of taping after finger flexor tendon pulley ruptures in rock climbers.

Flexor tendon pulley ruptures are the most common injury in rock climbers. Therapeutic standards usually include a prolonged use of taping applied as a replacement for the lost pulley in a circular fashion at the base of the proximal phalanx. Our biomechanical considerations, however, suggest a new taping method, the H-tape. The purpose of the study is to evaluate whether this new taping method...

متن کامل

Reconstruction of the flexor pollicis longus tendon ruptured, but untreated, during infancy.

We treated 3 patients who had ruptured the flexor pollicis longus (FPL) tendon during infancy and which had not been repaired. A two-stage surgical procedure, using a silicone rod, was performed to reconstruct the tendon, and favorable thumb flexion was obtained. A favorable outcome was obtained, even if the gliding of the silicone rod had been poor after the first stage procedure. When the sca...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of applied biomechanics

دوره 27 4  شماره 

صفحات  -

تاریخ انتشار 2011