Studies of Systematic Uncertainties in the HiRes - II Measurement of the UHECR Spectrum

ثبت نشده
چکیده

Presenter: A. Zech ([email protected]), fra-zech-A-abs1-he14-poster We present studies of systematic uncertainties in the measurement of the ultra-high energy cosmic ray (UHECR) spectrum with the FADC detector of the High Resolution Fly's Eye experiment (HiRes-II). One source of uncertainties lies in the simulation of the energy dependent aperture of the air fluorescence detector. We study the impact of changes in the energy spectrum and composition that are used as input to the aperture simulation. We also compare aperture estimates for two different hadronic interaction models-QGSJet and SIBYLL. Systematic uncertainties may further be introduced by the modeling of the aerosol component of the atmosphere. We have repeated the HiRes-II monocular analysis using an atmospheric database with hourly entries instead of our measurement of the average aerosol content. We will discuss changes in reconstructed energies and in the resulting spectrum.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Measurement of the UHECR Spectrum with the HiRes FADC Detector

We have measured the energy spectrum of ultra-high energy cosmic rays (UHECR) with the HiRes FADC detector (HiRes-2) in monocular mode. A detailed Monte Carlo simulation of the detector response to air showers has been used to calculate the energy dependent acceptance of the air fluorescence detector. The measured spectrum complements the measurement by the HiRes-1 detector down to lower energi...

متن کامل

Effects of the energy error distribution of fluorescence telescopes on the UHECR energy spectrum

The measurement of the ultra high energy cosmic ray (UHECR) spectrum is strongly affected by uncertainties on the reconstructed energy. The determination of the presence or absence of the GZK cutoff and its position in the energy spectrum depends not only on high statistics but also on the shape of the energy error distribution. Here we determine the energy error distribution for fluorescence t...

متن کامل

Observation of the GZK Cutoff Using the HiRes Detector

The High Resolution Fly’s Eye (HiRes) experiment has observed the GZK cutoff. HiRes observes two features in the ultra-high energy cosmic ray (UHECR) flux spectrum: the Ankle at an energy of 4 × 10 eV and a high energy suppression at 6×10 eV. The later feature is at exactly the right energy for the GZK cutoff according to the E1/2 criterion. HiRes cannot claim to observe a third feature at lowe...

متن کامل

ar X iv : a st ro - p h / 06 07 09 4 v 2 2 4 M ay 2 00 7 Studies of systematic uncertainties in the estimation of the monocular aperture of the HiRes experiment

We have studied several sources of systematic uncertainty in calculating the aperture of the High Resolution Fly’s Eye experiment (HiRes) in monocular mode, primarily as they affect the HiRes-II site. The energy dependent aperture is determined with detailed Monte Carlo simulations of the air showers and the detector response. We have studied the effects of changes to the input energy spectrum ...

متن کامل

ar X iv : a st ro - p h / 06 07 09 4 v 1 6 J ul 2 00 6 Studies of systematic uncertainties in the estimation of the monocular aperture of the HiRes experiment

We have studied several sources of systematic uncertainty in calculating the aperture of the High Resolution Fly’s Eye experiment (HiRes) in monocular mode, primarily as they affect the HiRes-II site. The energy dependent aperture is determined with detailed Monte Carlo simulations of the air showers and the detector response. We have studied the effects of changes to the input energy spectrum ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2005