A simple subcritical chromatographic test for an extended ODS high performance liquid chromatography column classification.
نویسندگان
چکیده
This paper describes a new test designed in subcritical fluid chromatography (SFC) to compare the commercial C18 stationary phase properties. This test provides, from a single analysis of carotenoid pigments, the absolute hydrophobicity, the silanol activity and the steric separation factor of the ODS stationary phases. Both the choice of the analytical conditions and the validation of the information obtained from the chromatographic measurements are detailed. Correlations of the carotenoid test results with results obtained from other tests (Tanaka, Engelhard, Sander and Wise) performed both in SFC and HPLC are discussed. Two separation factors, calculated from the retention of carotenoid pigments used as probe, allowed to draw a first classification diagram. Columns, which present identical chromatographic behaviors are located in the same area on this diagram. This location can be related to the stationary phase properties: endcapping treatments, bonding density, linkage functionality, specific area or silica pore diameter. From the first classification, eight groups of columns are distinguished. One group of polymer coated silica, three groups of polymeric octadecyl phases, depending on the pore size and the endcapping treatment, and four groups of monomeric stationary phases. An additional classification of the four monomeric groups allows the comparison of these stationary phases inside each group by using the total hydrophobicity. One hundred and twenty-nine columns were analysed by this simple and rapid test, which allows a comparison of columns with the aim of helping along their choice in HPLC.
منابع مشابه
Simple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملSimple High-Performance Liquid Chromatographic Method for Determination of Ciprofloxacin in Human Plasma
A rapid, simple and sensitive high-performance liquid chromatography method was developed for determination of ciprofloxacin in plasma by means of ultraviolet detection. Ofloxacin was used as an internal standard and separation carried on a Novapak C18 column using a mobile phase of 0.01 M phosphate buffer (pH =2.6): methanol (82: 18 v/v). Extraction of drug was performed from plasma by liquid-...
متن کاملTemperature effect on peak width and column efficiency in subcritical water chromatography.
Subcritical water has been recently employed as the mobile phase to eliminate the use of organic solvents in reversed-phase liquid chromatography. Although the influence of temperature on retention in subcritical water chromatography has been reported, the temperature effect on peak width and column efficiency has not yet been quantitatively studied. In this work, several polar and chlorinated ...
متن کاملA Sensitive Liquid Chromatographic Method for the Analysis of Clarithromycin with Pre-Column Derivatization: Application to a Bioequivalence Study
Objective(s) A sensitive liquid chromatographic method for the analysis of clarithromycin- a macrolide antibiotic- in human serum, using pre-column derivatization with 9-fluorenylmethyl chloroformate (FMOC-Cl) is described. Materials and Methods The method involved liquid-liquid extraction of the drug and an internal standard (amantadine) followed by pre-column derivatization of the analytes...
متن کاملDetermination of 18 ?-Glycyrrhetinic Acid in Glycyrrhiza glabra L. Extract by HPLC
A high performance liquid chromatography method was studied for determination of 18 ?-glycyrrhetinic acid in Glycyrrhiza glabra L. (licorice) extract. The operating condition were C-18 reversed phase column (VP-ODS, (250×4.6 mm, 5 mm)) at room temperature, acetonitril/phosphoric acid (3/1) as mobile phase, at flow rate of 0.6ml/min (0-8min), 0.4ml/min (8-20min) and UV detection at 230 nm. The...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of chromatography. A
دوره 1100 1 شماره
صفحات -
تاریخ انتشار 2005