Optimization of analog-circuit motion correction for liver scintigraphy.

نویسنده

  • R F Mould
چکیده

Respiratory motion customarily degrades the resolution of a routine hepatic scintigram. We have analyzed four analog motion-correction methods and have measured their abilities to maintain good spatial resolution over a broad range of liver scintigraphy parameters. The analog circuit described can maintain the spatial resolution of the scintillation camera within 2 mm of the full width at half maximum of the stationary point-sread function. Experiments show that clinicians require about 50% greater film-density contrast to detect a 2-cm-diam. lesion if motion correction is not used. In 14% of the cases studied, the addition of a motion-corrected anterior view to the usual four-view liver study (performed without motion correction) resulted in a changed clinical interpretation. We conclude that analog motion correction should be provided in all scintillation cameras used for liver scintigraphy.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Optimal fast digital error correction method of pipelined analog to digital converter with DLMS algorithm

In this paper, convergence rate of digital error correction algorithm in correction of capacitor mismatch error and finite and nonlinear gain of Op-Amp has increased significantly by the use of DLMS, an evolutionary search algorithm. To this end, a 16-bit pipelined analog to digital converter was modeled. The obtained digital model is a FIR filter with 16 adjustable weights. To adjust weights o...

متن کامل

Design of a Single-Layer Circuit Analog Absorber Using Double-Circular-Loop Array via the Equivalent Circuit Model

A broadband Circuit Analogue (CA) absorber using double-circular-loop array is investigated in this paper. A simple equivalent circuit model is presented to accurately analyze this CA absorber. The circuit simulation of the proposed model agrees well with full-wave simulations. Optimization based the equivalent circuit model, is applied to design a single-layer circuit analogue absorber using d...

متن کامل

Multi Objective Inclined Planes System Optimization Algorithm for VLSI Circuit Partitioning

In this paper multi objective optimization problem for partitioning process of VLSI circuit optimization is solved using IPO algorithm. The methodology used in this paper is based upon the dynamic of sliding motion along a frictionless inclined plane. In this work, modules and elements of the circuit are divided into two smaller parts (components) in order to minimize the cutsize and area imbal...

متن کامل

Automatic Design Centering of Analog Integrated Circuits Based on the Generalized Boundary Curve of Multiple Robustness Objectives

In this report a method for the design centering of analog circuits, based on worstcase distances (WCD) is presented. In order to keep the linearization error small, only the WCDs and not the strongly nonlinear objective function itself is linearized. For the resulting nonlinear trust-region problem the generalized boundary curve (GBC) is derived as a method to determine a solution with a good ...

متن کامل

Improving adaptive resolution of analog to digital converters using least squares mean method

This paper presents an adaptive digital resolution improvement method for extrapolating and recursive analog-to-digital converters (ADCs). The presented adaptively enhanced ADC (AE-ADC) digitally estimates the digital equivalent of the input signal by utilizing an adaptive digital filter (ADF). The least mean squares (LMS) algorithm also determines the coefficients of the ADF block. In this sch...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of nuclear medicine : official publication, Society of Nuclear Medicine

دوره 19 9  شماره 

صفحات  -

تاریخ انتشار 1978