Accurate assessment of aortic stenosis with intravenous contrast.

نویسندگان

  • Girish Dwivedi
  • Michael Hickman
  • Roxy Senior
چکیده

We came across an interesting case of calcific aortic stenosis in which severity was inaccurately assessed on two-dimensional and Doppler echocardiogram resulting in catheterization. Use of intravenous transpulmonary contrast agent enhanced the Doppler signal enabling better quantification of the transvalvular gradient. Use of contrast in such difficult to image patients is very useful in establishing a correct diagnosis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The first performance of myocardial perfusion scintigraphy, post intravenous Dipyridamole injection

SUMMARY Dipyridamolc-Thallium imaging is a relatively safe and accurate method to evaluate myocardial perfusion in patients who arc unable to exercise to a maximal exertion (5,6,8,9). A 51year-old woman was admitted to Taleghani hospital with clinical symptoms and signs of coronary artery disease. Intravenous dipyridamote-Thallium scan was performed in this case. In multiple views obtained f...

متن کامل

SUPRAVALVAR AORTIC STENOSIS IN CHILDREN REPORT OF THIRTEEN CASES

During 15 years from 1975 to 1990, thirteen cases of supravalvar aortic stenosis were admitted at the pediatrics department of Shahid Rajai Heart Hospital, Tehran. All patients were subjected to cardiac catheterization and a angiocardiography. Patients ranged in age from 3.5 years to 14 years with a mean of 8.7 years. Seventy seven percent of childen were male. Eight cases (61.5%) had Wil...

متن کامل

Peak velocity estimation in aortic stenosis patients using a fast three-directional two-dimensional phase contrast technique in a single breath-hold: comparison to unidirectional phase contrast MRI and transthoracic echocardiography

Background Assessment of aortic valve stenosis (AVS) severity is crucial for valve replacement indication and is typically performed by transthoracic Doppler-echocardiography (TTE). However, TTE may be suboptimal in up to 30% of patients. Unidirectional through-plane phase-contrast magnetic resonance imaging (1Dir PC-MRI) is the most common MRI technique used to quantify peak velocities (Vpeak)...

متن کامل

Aortic Stenosis assessment with a 3-directional phase contrast magnetic resonance technique. Comparison to transthoracic echocardiography

Background Transthoracic Doppler-echocardiography (TTE) is the standard clinical method for diagnosis and staging of aortic stenosis (AS). AS staging is based on measurement of aortic peak velocity, transvalvular gradient, and calculation of aortic valve area. Unidirectional throughplane phase-contrast magnetic resonance imaging (1DPC-MRI) has been widely applied in clinical imaging to quantify...

متن کامل

مقایسه نتایج درمانی بالون والوپلاستی و والوتومی جراحی در بیماران مبتلا به تنگی مادرزادی دریچه آئورت در پیگیری 6 ساله در بخش کودکان بیمارستان قلب شهید رجایی تهران

Background: Balloon valvuloplasty is a relatively new technique for relief of obstruction of aortic valve. The primary results of this procedure are similar to surgical valvotomy with fewer complications and mortality. Materials and methods: One hundred fifty-five patients with congenital aortic stenosis were enrolled in this study over a period of 6 years (1991-1997). Participants were all un...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of echocardiography : the journal of the Working Group on Echocardiography of the European Society of Cardiology

دوره 7 2  شماره 

صفحات  -

تاریخ انتشار 2006