Separation and determination of acetyl-glutamine enantiomers by HPLC–MS and its application in pharmacokinetic study
نویسندگان
چکیده
A high-performance liquid chromatography coupled with mass spectrometry (HPLC-MS) method was established for the separation and determination of acetyl-glutamine enantiomers (acetyl-L-glutamine and acetyl-D-glutamine) simultaneously. Baseline separation was achieved on Chiralpak AD-H column (250 mm × 4.6 mm, 5 µm). n-Hexane (containing 0.1% acetic acid) and ethanol (75:25, v/v) were used as mobile phase at a flow rate of 0.6 mL/min. The detection was operated in the negative ion mode with an ESI source. [M-H]-m/z 187.0540 for enantiomers and [M-H]-m/z 179.0240 for aspirin (IS) were selected as detecting ions. The linear range of the calibration curve for each enantiomer was 0.05-40 µg/mL. The precision of this method at concentrations of 0.5-20 µg/mL was within 7.23%, and the accuracy was 99.81%-107.81%. The precision at LOQ (0.05 µg/mL) was between 16.28% and 17.56%, which was poor than that at QC levels. The average extraction recovery was higher than 85% for both enantiomers at QC levels. The pharmacokinetics of enantiomers was found to be stereoselective. There was not chiral inversion in vivo or in vitro between enantiomers.
منابع مشابه
Stereospecific Determination of Mefloquine in Whole Blood by HPLC
Mefloquine, as a racemic mixture, is used for the treatment and prophylaxis of malaria. Stereoselective pharmacodynamic and pharmacokinetic differences has been observed for mefloquine. In this study a modified stereoselective HPLC method is presented for determination of mefloquine (MFQ) enantiomers in whole blood. The assay involved liquid-liquid extraction of MFQ from biological fluids with ...
متن کاملاندازهگیری مبودیپین در مایعات بیولوژیک با روش HPLC و کاربرد این دارو در مطالعه فارماکوکینتیک در موش صحرایی An HPLC Method for Determination of Mebudipine in Biological Fluids in Rats and its Application in Pharmacokinetic Study
Background & Aim: Mebudipine is a calcium antagonist drug which is used to treat blood pressure. A new high performance liquid chromatography(HPLC) system for the determination of a new 1, 4-dihydropyridine, mebudipine, in rat plasma and other biological fluids was developed in this study for the first time. Materials & Methods: To 1 ml of rat plasma and/or other biological fluids, 0.5 ...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملGender Dependency in Streoselective Pharmacokinetics of Tramadol and Its Phase I Metabolites in Relation to CYP2D6 Phenotype in Iranian Population
The stereoselective pharmacokinetic of Tramadol (T) and its main metabolites concerning the influence of CYP2D6 phenotype and gender on the phase I metabolism of this compound was studied after administration of 100 mg single oral dose of racemic T to 24 male and female subjects. The pharmacokinetic parameters were estimated from plasma concentrations of the analytes enantiomers. The metabolic ...
متن کاملA Rapid, Simple, Liquid Chromatographic-Electrospray Ionization, Ion Trap Mass Spectrometry Method for the Determination of Finasteride in Human Plasma and its Application to Pharmacokinetic Study
A fast, accurate, sensitive, selective and reliable method using reversed-phase high performance liquid chromatography coupled to electrospray ionization ion trap mass spectrometry was developed and validated for the determination of finasteride in human plasma. After protein precipitation with perchloric acid, satisfactory separation was achieved on a Zorbax Eclipse® C8 analytical column u...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017