BACKGROUND Loosening of screws is a common problem in orthopedic and maxillofacial surgery. Modifying the implant surface to improve the mechanical strength of screws has been tried and reported. We developed screws coated with fibroblast growth factor-2 (FGF-2)-apatite composite layers. We then showed, in a percutaneous external fixation model, that this composite layer had the ability to hold and release FGF-2 slowly, thereby reducing the risk of pin tract infection of the percutaneous external fixation. The objective of the current study was to clarify the effect of FGF-2-apatite composite layers on titanium screws on bone formation around the screw. METHODS We analyzed samples of previously performed animal experiments. The screws were coated with FGF-2-apatite composite layers by immersing them in supersaturated calcium phosphate solutions containing FGF-2. Then, the uncoated, apatite-coated, and FGF-2-apatite composite layer-coated screws were implanted percutaneously in rabbits. Finally, using inflammation-free histological sections, we histomorphometrically assessed them for the presence of bone formation. Weibull plot analysis was then applied to the data. RESULTS On average, screws coated with FGF-2-apatite composite layers showed a significantly higher bone apposition rate than the uncoated or apatite-coated screws. Although the difference in the average bone apposition rate was small, the FGF-2-apatite composite layers produced a significant, marked reduction in the incidence of impaired bone formation around the screw compared with the incidence in the absence of FGF-2 (uncoated and apatite-coated screws). The probability of resulting in a bone apposition rate equal to or less than 63.75%, for example, is 3.5 × 10-4 for screws coated with the FGF-2-apatite composite layers versus 0.05 for screws in the absence of FGF-2. CONCLUSIONS FGF-2-apatite composite layer coating significantly reduced the risk of impaired bone apposition to the screw. Thus, it is feasible to use titanium screws coated with FGF-2-apatite composite layers as internal fixation screws to decrease the risk of loosening.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

The Calcium Phosphate Matrix of FGF-2-Apatite Composite Layers Contributes to Their Biological Effects

The purpose of the present study was to fabricate fibroblast growth factor (FGF)-2-apatite composite layers on titanium (Ti) pins in one step at 25 °C using a supersaturated calcium phosphate (CaP) solution, and to evaluate the physicochemical characteristics and biological effects of the coated Ti pins compared with coated Ti pins fabricated at 37 °C. Ti pins were immersed in a supersaturated ...

متن کامل

Coating of Carbon Fibre Reinforced PEEK Implants with Titanium by Vapour Plasma Spraying for Improved Bone Apposition

Introduction: The success of an orthopaedic implant depends on several factors, such as implant material properties, design and fixation technique as well as bone apposition around the implant. Polyetheretherketone (PEEK) is a composite thermoplastic biomaterial exhibiting biochemical and biomechanical properties suitable for load-bearing orthopaedic implants. Two advantages of carbon fibre rei...

متن کامل

Surface modification for titanium implants by hydroxyapatite nanocomposite

Background: Titanium (Ti) implants are commonly coated with hydroxyapatite (HA). However, HA has some disadvantages such as brittleness, low tensile strength and fracture toughness. It is desirable to combine the excellent mechanical properties of ZrO2 and the chemical inertness of Al2O3 with respect to the purpose of this project which was coating Ti implants with HA-ZrO2-Al2O3 to modify the s...

متن کامل

Biomimetic Apatite Coating as an Alternative to Plasma-sprayed Hydroxyapatite Coating for Promotion of Bone Apposition-the Coating Formation and in Vitro Study

Introduction: The calcium phosphate ceramics, in particular hydroxyapatite ( HA), has shown to be capable of conducting bone formation and forming a chemical bond to bone. Because of this osteoconductivity, HA ceramic has been applied in joint reconstruction in the form of coating on joint implants such as hip stems by plasma spraying technique. Direct bone apposition has been repeatedly demons...

متن کامل

Initial bone regeneration around fenestrated implants in Beagle dogs using basic fibroblast growth factor-gelatin hydrogel complex with varying biodegradation rates.

PURPOSE The purpose of this study was to compare the effectiveness of fast and slow biodegradation of basic fibroblast growth factor (bFGF)-gelatin hydrogel complex on bone regeneration around fenestrated implants as a new augmentation drug delivery system. METHODS Nine titanium implants (3.3mm diameter and 10mm length) were placed into the edentulous areas of the mandibles of three adult bea...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 12  شماره 

صفحات  -

تاریخ انتشار 2017