Measurement of Articular Cartilage Thickness Using a 3D Image Reconstructed from B-mode Ultrasonography Mechanical Scans -Comparison with MRI-derived Data-

ثبت نشده
چکیده

Mechanical Scans -Comparison with MRI-derived DataOhashi, S; +Ohnishi, I; Matsumoto, T; Bessho, M; Matsuyama, J; Tobita, K; Kaneko M; Nakamura, K +Department of Orthopaedic Surgery, Faculty of Medicine, University of Tokyo, Tokyo, Japan [email protected] INTRODUCTION Although articular cartilage thickness has previously been quantified using B-mode ultrasonography (US) [1, 2], thicknesses in those studies were measured 2-dimensionally using B-mode slice images. Cartilage thickness has also been quantified by creation of 3-dimensional (3D) models from MRI data [3, 4], but this approach has not been adapted to US. The purpose of this study was to develop a method to measure 3D articular cartilage thickness at the femoral condyle using B-mode US and to compare results with 3D measurements using MRI to clarify the feasibility of US in clinical evaluations of articular cartilage. OBJECTIVES AND METHODS US B-mode image acquisition Subjects comprised 2 healthy male volunteers (age, 37 and 59 years) and 2 male patients with knee osteoarthritis (age, 73 and 81 years) who provided written informed consent prior to participation in the study. The study protocol was approved by the ethics committee of our institution. A B-mode 10.0-MHz linear ultrasound probe (UST-5411; Aloka, Tokyo, Japan) connected to an ultrasound device (Prosound ALPHA 10; Aloka) was attached to a probe scanner stabilized by a holding arm, allowing the ultrasound probe to move along the surface of the flexed knee (Fig. 1A). The base of the holding arm was rotated by a gear and data on angle of rotation of the arm was transferred to the ultrasound device by an encoder. Scans with angle data were recorded. The medial surface of the right knee of each participant was scanned using the ultrasound probe with the knee flexed at 120 (Fig. 1B) so the cartilage surface of the femoral medial condyle could be visualized by US. The US probe was attached to the arm so the US imaging plane was parallel to the arm plane, allowing the imaging plane to rotate around the center axis of the encoder, which was coaxial with the medial-lateral axis of the femoral condyle. The range of the angle of rotation for the arm was 0-80 and the US B-mode images (total, 101 images) were acquired every 0.8 (Fig. 2A). System settings were optimized to image the cartilage surface (tissue harmonic, 420 pixels × 468 pixels; pixel size, 0.0855 mm  0.0855 mm).

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Active contour segmentation of MR images for quantitative cartilage measurements: computational method, interobserver reproducibility and comparison to manual delineation

Introduction Many joint deseases are related to damages of the articular cartilage layer. These damages may be quantified by measurements of the cartilage thickness distribution throughout the joint surface, supplying the physician with a paramter allowing to stage joint dysfunctions or to monitor therapeutic interventions, such as chondroprotective treatment or cartilage transplantation. With ...

متن کامل

Comparison of Three-Dimensional Double-Echo Steady-State Sequence with Routine Two-Dimensional Sequence in the Depiction of Knee Cartilage

Introduction: There are some routine two-dimensional sequences, including short tau inversion recovery (STIR), T2-weighted fast-spin echo (T2W-FSE), and proton-density fast spin-echo for diagnosing osteoarthritis and lesions of the knee cartilage. However, these sequences have some disadvantages, such as long scan time, inadequate spatial resolution, and suboptimal tis...

متن کامل

Evaluation of the Accuracy of Articular Cartilage Thickness Measurement by Conventional and Real-time Spatial Compound Ultrason

Compound Ultrasonography Ohashi, S; +Ohnishi, I; Matsumoto, Bessho, T; Matsuyama, J; M; Tobita, K; Kaneko M; Nakamura, K + Department of Orthopaedic Surgery, Faculty of Medicine, University of Tokyo, Tokyo, Japan [email protected] INTRODUCTION Articular cartilage thickness has previously been quantified by Bmode ultrasonography [1, 2]. However, cartilage surface and cartilagebone bor...

متن کامل

Validation of magnetic resonance imaging for measurement of equine articular cartilage and subchondral bone thickness.

OBJECTIVE To validate use of magnetic resonance images (MRIs) for measurement of equine articular cartilage and subchondral bone thickness by comparison with measurements in histologic specimens. SAMPLE POPULATION 32 cadaveric carpal joints from 16 horses. PROCEDURE Magnetic resonance imaging was performed by use of 3-dimensional fast spoiled gradient echo (SPGR) and T2* 3-dimensional fast ...

متن کامل

The Use of Active Shape Models for MakingThickness Measurements of Articular Cartilage fromMR

Previously reported studies to quantify articular cartilage have used labour-intensive manual or semi-automatic data-driven techniques, demonstrating high accuracy and precision. However, none has been able to automate the segmentation process. This paper describes a fast, automatic, modelbased approach to segmentation and thickness measurement of the femoral cartilage in 3D T1-weighted images ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010