Effects of one-lung ventilation on thermodilution-derived assessment of cardiac output.

نویسندگان

  • C Trepte
  • S Haas
  • N Meyer
  • M Gebhardt
  • M S Goepfert
  • A E Goetz
  • D A Reuter
چکیده

BACKGROUND Cardiac output (CO) monitoring can be useful in high-risk patients during one-lung ventilation (OLV), but it is unclear whether thermodilution-derived CO monitoring is valid during OLV. Therefore, we compared pulmonary artery (CO(PATD)) and transcardiopulmonary thermodilution (CO(TPTD)) with an experimental reference in a porcine model. METHODS CO(PATD) and CO(TPTD) were measured in 23 pigs during double-lung ventilation (DLV) and 15 min after the onset of OLV, during conditions of normovolaemia and after haemorrhage. An ultrasonic flow probe placed around the pulmonary artery (CO(PAFP)) was used for reference. RESULTS The range of CO in these experiments was 1.5-3 litre min(-1). Normovolaemia: during DLV and conditions of normovolaemia, the mean (95% limits of agreement) bias for CO(PATD) compared with CO(PAFP) was -0.05 (-0.92 and 0.83) litre min(-1), and 0.58 (-0.40 and 1.55) litre min(-1) for CO(TPTD). During OLV, the bias for CO(PATD) remained unchanged at 0.08 (-0.51 and 0.66) litre min(-1), P=0.15, and the bias for CO(TPTD) increased significantly to 0.85 (0.05 and 1.64) litre min(-1), P=0.047. Hypovolaemia: during DLV, the bias for CO(PATD) compared with CO(PAFP) was 0.22 (-0.20 and 0.66) litre min(-1) and for CO(TPTD) was 0.60 (0.12 and 1.10) litre min(-1). There was no significant change of bias during OLV for CO(PATD) [0.30 (-0.10 and 0.70) (litre min(-1)), P=0.25] or bias CO(TPTD) [0.72 (0.21 and 1.22) (litre min(-1)), P=0.14]. Trending ability during OLV, quantified by the mean of angles θ, showed good values for both CO(PATD) (θ=11.2°) and CO(TPTD) (θ=1.3°). CONCLUSIONS CO(TPTD) is, to some extent, affected by OLV, whereas CO(PATD) is unchanged. Nonetheless, both methods provide an acceptable estimation of CO and particularly of relative changes of CO during OLV.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Comparison between cardiac output values measured by thermodilution and partial carbon dioxide rebreathing in patients with acute lung injury.

CONTEXT Thermodilution, which is considered to be a standard technique for measuring the cardiac output in critically ill patients, is not free from relevant risks. There is a need to find alternative, noninvasive, automatic, simple and accurate methods for monitoring cardiac output at the bedside. OBJECTIVE To compare cardiac output measurements by thermodilution and partial carbon dioxide r...

متن کامل

Cardiovascular changes during drainage of pericardial effusion by thoracoscopy.

BACKGROUND Cardiovascular changes during drainage of pericardial effusion are not well understood, and most studies are of systemic effects and not of right ventricular performance. Thoracoscopy is not widely used to drain pericardial effusions because of haemodynamic changes in relation to the use of single lung ventilation. PATIENTS AND METHODS We studied 16 patients undergoing partial peri...

متن کامل

Effects of reduced rebreathing time, in spontaneously breathing patients, on respiratory effort and accuracy in cardiac output measurement when using a partial carbon dioxide rebreathing technique: a prospective observational study

INTRODUCTION New technology using partial carbon dioxide rebreathing has been developed to measure cardiac output. Because rebreathing increases respiratory effort, we investigated whether a newly developed system with 35 s rebreathing causes a lesser increase in respiratory effort under partial ventilatory support than does the conventional system with 50 s rebreathing. We also investigated wh...

متن کامل

Assessing the impacts of total liquid ventilation on left ventricular diastolic function in a model of neonatal respiratory distress syndrome

BACKGROUND Filling the lung with dense liquid perfluorocarbons during total liquid ventilation (TLV) might compress the myocardium, a plausible explanation for the instability occasionally reported with this technique. Our objective is to assess the impacts of TLV on the cardiovascular system, particularly left ventricular diastolic function, in an ovine model of neonatal respiratory distress s...

متن کامل

CLINICAL INVESTIGATIONS The open lung concept: effects on right ventricular afterload after cardiac surgery

Methods.We studied 24 stable patients after coronary artery surgery and=or valve surgery with cardiopulmonary bypass. Patients were randomly assigned to OLC or conventional mechanical ventilation (CMV). In the OLC group, recruitment manoeuvres were applied until PaO2=FIO2 was greater than 50 kPa (reflecting anopen lung). This valuewasmaintained by sufficient positive airway pressure. In the CMV...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • British journal of anaesthesia

دوره 108 6  شماره 

صفحات  -

تاریخ انتشار 2012