Development of broadband cavity ring-down spectroscopy for biomedical diagnostics of liquid analytes.

نویسندگان

  • S-S Kiwanuka
  • T K Laurila
  • J H Frank
  • A Esposito
  • K Blomberg von der Geest
  • L Pancheri
  • D Stoppa
  • C F Kaminski
چکیده

We present a spectrometer for sensitive absorption measurements in liquids across broad spectral bandwidths. The spectrometer combines the unique spectral properties of incoherent supercontinuum light sources with the advantages of cavity ring-down spectroscopy, which is a self-calibrating technique. A custom-built avalanche photodiode array is used for detection, permitting the simultaneous measurement of ring-down times for up to 64 different spectral components at nanosecond temporal resolution. The minimum detectable absorption coefficient was measured to be 3.2 × 10(-6) cm(-1) Hz(-1/2) at 527 nm. We show that the spectrometer is capable of recording spectral differences in trace levels of blood before and after hemolysis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Use of broadband, continuous-wave diode lasers in cavity ring-down spectroscopy for liquid samples.

Cavity ring-down spectroscopy (CRDS) is an extremely sensitive absorption technique that has been applied primarily to gas samples, which are characterized by having narrow absorption features. Recently, CRDS has also been applied to liquid samples, which have broad absorption features. The use of small inexpensive diode lasers as light sources for liquid samples is demonstrated. The low cost c...

متن کامل

Cavity ring-down spectroscopy for quantitative absorption measurements

We examine under what conditions cavity ring-down spectroscopy ~CRDS! can be used for quantitative diagnostics of molecular species. We show that CRDS is appropriate for diagnostics of species whose absorption features are wider than the spacing between longitudinal modes of the optical cavity. For these species, the absorption coefficient can be measured by CRDS without a knowledge of the puls...

متن کامل

Sensitive method for the kinetic measurement of trace species in liquids using cavity enhanced absorption spectroscopy with broad bandwidth supercontinuum radiation.

A novel spectrometer for the rapid and sensitive detection of liquid phase analytes at trace concentrations is presented. Broad bandwidth supercontinuum radiation was coupled into a linear optical cavity incorporating an intracavity liquid-sample cuvette. Cavity enhanced absorption spectra of trace species covering more than 300 nm were acquired on time scales of milliseconds. Single shot acqui...

متن کامل

Direct monitoring of absorption in solution by cavity ring-down spectroscopy.

Cavity ring-down spectroscopy is applied to the liquid phase by placing the target solution directly into the optical cavity. We demonstrate that solutions in the cavity can be stirred and more importantly monitored in a flow. We report a minimum detectable absorption of 10(-6) cm(-1) for a range of organic solvents. This detection limit corresponds to picomolar concentrations for strong absorb...

متن کامل

Application of quantum cascade lasers to trace gas analysis

Quantum cascade (QC) lasers are virtually ideal mid-infrared sources for trace gas monitoring. They can be fabricated to operate at any of a very wide range of wavelengths from ∼ 3 μm to ∼ 24 μm. Seizing the opportunity presented by mid-infrared QC lasers, several groups world-wide are actively applying them to trace gas sensing. Real world applications include environmental monitoring, industr...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical chemistry

دوره 84 13  شماره 

صفحات  -

تاریخ انتشار 2012