Serum alpha-fetoprotein: I. Evaluation of quantitative assays adapted to automated immunoassay systems.
نویسندگان
چکیده
Serum alpha-fetoprotein (s.AFP) has been established as a useful tool in monitoring of high-risk pregnancies, as an indicator of fetal neural tube defects, and has been used as an adjunct tumor marker and for monitoring therapeutic efficacy in the treatment of certain tumors. To date, the methods for measuring s.AFP are based upon the immunologic principle and are manual methods. The purpose here is to relate the evaluation of two automated systems for the assay of s.AFP. The automated systems are based upon the following immunoassay methods: a microparticle capture enzyme separation and final quantitation by reflectance fluorescence, and a solid phase 'sandwich' separation coupled with enzyme activity measurement (EIA). The reference method is a competitive binding radioimmunoassay. It has been found by us that the automated methods directly transfer analytically with the manual assay. All methods are referenced to the same standard (WHO 1st Intl. Std. for AFP 72/225).
منابع مشابه
Serum alpha-fetoprotein: II. Clinical evaluation of two automated immunoassays for maternal serum screening.
A prospective clinical evaluation is reported for analysis of maternal serum alpha fetoprotein (s.AFP) testing by recently developed enzymeimmunoassay automated systems. The reference method for the study was a manual competitive binding radioimmunoassay which has been utilized by us in the Maternal Serum AFP Screening Program at the Medical University of South Carolina for the past five years....
متن کاملPerformance evaluation of automated immunoassays on the Technicon Immuno 1 system.
We performed an immunoassay evaluation for various analytes on a fully automated random-access analyzer, the Technicon Immuno 1 system from Bayer Corp. This system involves latex agglutination, magnetic separation sandwich, and magnetic separation competitive immunoassay configurations. The evaluated analytes were thyrotropin (TSH), triiodothyronine, thyroxine, free thyroxine, follitropin, lutr...
متن کاملFacile resolution of alpha-fetoproteins and serum albumins by immobilized metal affinity chromatography.
We have explored immobilized metal affinity chromatography as a means of resolving alpha-fetoprotein from its homologous albumin, a problem perennially encountered in the purification of an alpha-fetoprotein or its detection. Human alpha-fetoprotein and human serum albumin were chromatographed on immobilized iminodiacetic acid charged with either Co2+, Ni2+, Cu2+, or Zn2+. Neither human alpha-f...
متن کاملEvaluation of serum AFP (α-fetoprotein) level in HBsAg carrier patients for diagnosis of hepatocellular carcinoma
Background: Hepatocellular carcinoma (HCC) is common all over the world as well as Iran. The incidence of HCC is higher in hepatitis B carriers and it is highly recommended to periodically screen these patients by serum alpha-fetoprotein (AFP) and liver ultrasound (US) every 6 months. We explore the diagnostic accuracy and the performance of (AFP) in cases of hepatitis B carriers as a scree...
متن کاملNew screening system for simultaneous determination of two marker proteins by homogeneous enzyme immunoassay.
AIMS To save time and labour in mass screening, by detecting two marker proteins on one specimen using only one test. METHODS alpha Fetoprotein and ferritin were chosen to demonstrate the principal of this system. The assay reagents were horseradish peroxidase (HRP)-labelled anti-alpha fetoprotein and HRP-labelled anti-ferritin antibodies. After the serum sample had been incubated with these ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of clinical and laboratory science
دوره 21 4 شماره
صفحات -
تاریخ انتشار 1991