Comparison of beamformers for EEG source signal reconstruction
نویسندگان
چکیده
Recently, several new beamformers have been introduced for reconstruction and localization of neural sources from EEG and MEG. Although studies have compared the accuracy of beamformers for localization of strong sources in the brain, a comparison of new and conventional beamformers for time-course reconstruction of a desired source has not been previously undertaken. In this study, 8 beamformers were examined with respect to several parameters, including variations in depth, orientation, magnitude, and frequency of the simulated source to determine their (i) effectiveness at time-course reconstruction of the sources, and (ii) stability of their performances with respect to the input changes. The spatial and directional pass-bands of the beamformers were estimated via simulated and real EEG sources to determine spatial resolution. White-noise spatial maps of the beamformers were calculated to show which beamformers have a location bias. Simulated EEG data were produced by projection via forward head modelling of simulated sources onto scalp electrodes, then superimposed on real background EEG. Real EEG was recorded from a patient with essential tremor and deep brain implanted electrodes. Gain – the ratio of SNR of the reconstructed time-course to the input SNR – was the primary measure of performance of the beamformers. Overall, minimum-variance beamformers had higher Gains and superior spatial resolution to those of the minimum-norm beamformers, although their performance was more sensitive to changes in magnitude, depth, and frequency of the simulated source. White-noise spatial maps showed that several, but not all, beamformers have an undesirable location bias. © 2014 Elsevier Ltd. All rights reserved.
منابع مشابه
Beamforming Techniques Applied in EEG Source Analysis
The electrical activity of the human brain causes time-varying potential differences on the head surface. The electroencephalogram (EEG) is a measurement of these potential differences between electrodes on the head. When the electrical brain activity is limited to a small region in the brain (e.g., during epileptic seizures), the source region within the brain can be localised by analysing the...
متن کاملSource Activity Correlation Effects on LCMV Beamformers in a Realistic Measurement Environment
In EEG and MEG studies on brain functional connectivity and source interactions can be performed at sensor or source level. Beamformers are well-established source-localization tools for MEG/EEG signals, being employed in source connectivity studies both in time and frequency domain. However, it has been demonstrated that beamformers suffer from a localization bias due to correlation between so...
متن کاملApplication of multi-source minimum variance beamformers for reconstruction of correlated neural activity
Linearly constrained minimum variance beamformers are highly effective for analysis of weakly correlated brain activity, but their performance degrades when correlations become significant. Multiple constrained minimum variance (MCMV) beamformers are insensitive to source correlations but require a priori information about the source locations. Besides the question whether unbiased estimates of...
متن کاملFieldTrip: Open Source Software for Advanced Analysis of MEG, EEG, and Invasive Electrophysiological Data
This paper describes FieldTrip, an open source software package that we developed for the analysis of MEG, EEG, and other electrophysiological data. The software is implemented as a MATLAB toolbox and includes a complete set of consistent and user-friendly high-level functions that allow experimental neuroscientists to analyze experimental data. It includes algorithms for simple and advanced an...
متن کاملCombination of Beamforming and Synchronization Methods for Epileptic Source Localization, using Simulated EEG Signals
Localization of sources in patients with focal seizure has recently attracted many attentions. In the severe cases of focal seizure, there is a possibility of doing neurosurgery operation to remove the defected tissue. The prosperity of this heavy operation completely depends on the accuracy of source localization. To increase this accuracy, this paper presents a new weighted beamforming method...