Methodology 77 CALIBRATION OF 3D KINEMATIC SYSTEMS USING 2D CALIBRATION PLATE

نویسندگان

  • Tomislav Pribanić
  • Joaquim Salvi
  • Mario Kasović
چکیده

3D kinematic systems based on the images acquired by cameras are one of the most popular tools for a human motion analyses. Prior to the actual reconstruction a camera calibration procedure is needed. Originally 3D calibration cages were utilized for that purpose, but nowadays a vast majority of commercial systems rely on the wand calibration. When the highest degree of accuracy is requested, than using 3D calibration cage is often recommended over the wand calibration. On the other hand, from a user point of view a wand calibration is generally regarded as the most user friendly. A substantial ‘intermediate’ solution would be using 2D calibration plate. Interestingly, there could be hardly found any trace that commercial 3D kinematic systems ever relied on 2D calibration plate. The purpose of this study was to investigate quantitative and qualitative aspects of calibrating the 3D kinematic system using 2D calibration plate.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Comparison between 2d Plate Calibration and Wand Calibration for 3d Kinematic Systems

Compared to a 2D plate camera calibration and a traditional 3D calibration cage, it is generally regarded that a wand-based camera calibration of 3D photogrammetric systems is more user-friendly. Not surprisingly, nowadays commercially available 3D kinematic systems for a human motion analysis are offering almost exclusively a wand calibration. Still a 2D calibration plate is continuously used ...

متن کامل

Camera Calibration for Underwater Applications: Effects of Object Position on the 3d Accuracy

The purpose of this study was to investigate the effects of object position in the working volume on the accuracy of 3D reconstruction, using four different camera calibration approaches: 1) the classical DLT, 2) the nonlinear DLT, 3) the 2D plate and 4) the wand calibration. The DVideo kinematic analysis system was used for underwater data acquisition. The system consisted of two gen-locked Ba...

متن کامل

3D reconstruction of human movement in a single projection by dynamic marker scaling

The three dimensional (3D) reconstruction of movement from videos is widely utilized as a method for spatial analysis of movement. Several approaches exist for a 3D reconstruction of movement using 2D video projection, most of them require the use of at least two cameras as well as the application of relatively complex algorithms. While a few approaches also exist for 3D reconstruction of movem...

متن کامل

Bore-Sight Calibration of Multiple Laser Range Finders for Kinematic 3D Laser Scanning Systems

The Simultaneous Localization and Mapping (SLAM) technique has been used for autonomous navigation of mobile systems; now, its applications have been extended to 3D data acquisition of indoor environments. In order to reconstruct 3D scenes of indoor space, the kinematic 3D laser scanning system, developed herein, carries three laser range finders (LRFs): one is mounted horizontally for system-p...

متن کامل

A Novel System-Level Calibration Method for Gimballed Platform IMU Using Optimal Estimation

An accurate calibration of inertial measurement unit errors is increasingly important as the inertial navigation system requirements become more stringent. Developing calibration methods that use as less as possible of IMU signals has 6-DOF gimballed IMU in space-stabilized mode is presented. It is considered as held stationary in the test location incorporating 15 di...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2008