Intraoperative three-dimensional versus two-dimensional echocardiography for left ventricular assessment.

نویسندگان

  • Alessandra Meris
  • Luisa Santambrogio
  • Gabriele Casso
  • Romano Mauri
  • Albin Engeler
  • Tiziano Cassina
چکیده

BACKGROUND Three-dimensional (3D) transesophageal echocardiography (TEE) technology is now widely used intraoperatively in cardiac surgery. Left ventricular (LV) measurements with 3D transthoracic echocardiography correlate better with cardiac magnetic resonance measurements compared with traditional two-dimensional (2D) transthoracic echocardiography. In this study, we compared intraoperative 3D TEE against 2D TEE regarding quantitative indices of LV function. METHODS We performed 2D TEE and 3D TEE examinations on 156 patients scheduled for elective cardiac surgery. Two-dimensional TEE images of midesophageal 4-, 2-chamber, and long-axis views were acquired. LV volumes and ejection fraction (EF) were calculated by Simpson's method. Three-dimensional full-volume images were recorded to calculate by a semiautomated procedure LV volumes (indexed to body surface area) and EF. 3D and 2D LV dimensions and function, image quality, time for acquisition/analyses, and reproducibility were compared by the Wilcoxon matched-pairs signed-ranks test. Pairwise differences between 3D and 2D data were compared using 95% prediction intervals (PIs) and Bland-Altman methodology. 3D volumes were also plotted against 2D volumes in scatter plots using a 3-zone error grid. RESULTS There was no significant difference between 3D and 2D in the estimation of EF (P = 0.227; median pairwise difference, -0.4% [95% PIs, -8.6% to 8.8%]). 3D LV indexed end-diastolic volumes (iEDVs) and end-systolic volumes (iESVs) were larger than 2D iEDVs (P < 0.001; median pairwise difference, 3.3 mL/m [95% PIs, -9.4 to 14.1 mL/m] and iESV: P < 0.001; median pairwise difference, 1.4 mL/m [95% PIs, -5.2 to 10.1 mL/m]). In the vast majority of cases (98.8% of cases for iEDV and 92.8% of cases for iESV), the difference between 2D and 3D TEE indexed volumes did not alter classification into normal, mildly to moderately dilated, or severely dilated volumes, as demonstrated by the 3-zone error grid analysis. Acquisition of 3D TEE image and analysis were not feasible in 4 patients (2.5%) for whom a quantitative 2D assessment of the LV was also impossible. 3D and 2D quality image was similar (P = 0.206). There was no difference in 3D versus 2D acquisition time (P = 0.805; pairwise difference = 2 seconds [95% PIs, -20 to 35 seconds]), but 3D analysis required more time (P < 0.001; pairwise difference = 117 seconds [95% PIs, 66 to 197 seconds]). Differences in repeated 3D versus 2D indexed volumes were not statistically significant, both considering interobserver reproducibility (iEDV: P = 0.125; pairwise difference, 0.26 ± 1.76 mL [95% PIs, -3.58 to 3.73 mL] and iESV: P = 0.126; pairwise difference, -0.16 ± 1.67 mL [95% PIs, -3.96 to 3.69 mL]) and intraobserver reproducibility (iEDV: P = 0.975; pairwise difference, -0.02 ± 1.20 mL [95% PIs, -2.32 to 2.08 mL] and iESV: P = 0.228; pairwise difference, -0.19 ± 1.13 mL [95% PIs, -2.47 to 2.53 mL]). CONCLUSIONS Intraoperative 3D TEE quantification of LV global function, image acquisition time, and reproducibility was not statistically different when compared with 2D TEE. It was however associated with calculation of larger LV volumes and a longer analysis time. Nevertheless, the 3-zone error grid analysis of the LV indexed volumes showed that the difference between 3D and 2D measurements does not affect the LV classification as normal, mildly to moderately dilated, or severely dilated.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Evaluation of strain and strain rate parameters using two-dimensional speckle-tracking echocardiography in patients with coronary artery disease (Research Article)

The study aimed was to measure left ventricular (LV) strain using speckle tracking echocardiography (STE) for assessment of LV function. Eighty-two subjects (mean age 57±9 years) with suspected chest pain underwent two-dimensional (2D)-echocardiography before coronary angiography. Conventional echocardiographic parameters were used for the assessment of LV function. Longitudinal strain and its ...

متن کامل

Three-dimensional Parametric Imaging for Intraoperative Quantification of Regional Left Ventricular Function in Ischemic Cardiomyopathy

© 2017 Annals of Cardiac Anaesthesia | Published by Wolters Kluwer Medknow The Editor, The intraoperative assessment of regional left ventricular (LV) function using three‐dimensional (3D) echocardiographic parametric imaging is evolving as the technique has a steep learning curve. The two‐dimensional wall motion score index is a subjective and a semi‐quantitative way of describing segmental co...

متن کامل

Intraoperative detection of myocardial ischemia in high-risk patients: electrocardiography versus two-dimensional transesophageal echocardiography.

Because acute segmental wall motion abnormalities (SWMAs) of the left ventricle are highly sensitive and specific indicators of myocardial ischemia, this study compared the incidence and significance of ischemia, as detected by two-dimensional transesophageal echocardiography and surface electrocardiography, during anesthesia and surgery in patients at high risk of myocardial ischemia. During s...

متن کامل

Accuracy of echocardiography versus electrocardiography in detecting left ventricular hypertrophy: comparison with postmortem mass measurements.

The accuracy of electrocardiography, M-mode echocardiography and two-dimensional echocardiography in predicting left ventricular hypertrophy was compared in 50 patients who came to autopsy within 6 months after the studies were performed. Several methods for determining left ventricular hypertrophy were examined for each of the three techniques. M-mode echocardiography was technically adequate ...

متن کامل

Intraoperative three-dimensional transesophageal echocardiography for evaluating an unusual structure in the left ventricular outflow tract: a case report

Intraoperative three-dimensional (3D) transesophageal echocardiography (TEE) facilitates an understanding of the complex cardiac pathology that is not fully delineated in a two-dimensional (2D) echocardiographic evaluation, and it suggests earlier and more precise surgical planning and intraoperative decision making. In the present case, the intraoperative 2D-TEE midesophageal long-axis view in...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Anesthesia and analgesia

دوره 118 4  شماره 

صفحات  -

تاریخ انتشار 2014