BACKGROUND People with stroke have a low peak aerobic capacity and experience increased effort during performance of daily activities. The purpose of this study was to examine test-retest reliability of a portable ergospirometry system in people with stroke during performance of functional activities in a field-test. Secondary aims were to examine the proportion of oxygen consumed during the field-test in relation to the peak-test and to analyse the correlation between the oxygen uptake during the field-test and peak-test in order to support the validity of the field-test. METHODS With simultaneous measurement of oxygen consumption, participants performed a standardized field-test consisting of five activities; walking over ground, stair walking, stepping over obstacles, walking slalom between cones and from a standing position lifting objects from one height to another. All activities were performed in self-selected speed. Prior to the field-test, a peak aerobic capacity test was performed. The field-test was repeated minimum 2 and maximum 14 days between the tests. ICC2,1 and Bland Altman tests (Limits of Agreement, LoA) were used to analyse test-retest reliability. RESULTS In total 31 participants (39% women, mean (SD) age 54.5 (12.7) years and 21.1 (14.3) months' post-stroke) were included. The ICC2,1 was ≥ 0.80 for absolute V̇O2, relative V̇O2, minute ventilation, CO2, respiratory exchange ratio, heart rate and Borgs rating of perceived exertion. ICC2,1 for total time to complete the field-test was 0.99. Mean difference in steady state V̇O2 during Test 1 and Test 2 was -0.40 (2.12) The LoAs were -3.75 and 4.51. Participants spent 60.7% of their V̇O2peak performing functional activities. Correlation between field-test and peak-test was 0.689, p = 0.001 for absolute and 0.733, p = 0.001 for relative V̇O2. CONCLUSIONS This study presents first evidence on reliability of oxygen uptake during performance of functional activities after stroke, showing very good test-retest reliability. The secondary analysis showed that the amount of energy spent during the field-test relative to the peak-test was high and the correlation between the two test was good, supporting the validity of this method.
منابع مشابه
Oxygen Consumption (V’O2) and physical Strainas measured by the occupational activity of cleaning personnel
Background The aim of the study was to determine the physical effort and energy expenditure needed over a working period of 45-60 min, specifically for the occupational activity of cleaning. The effort was demonstrated in absolute terms (V'O2), in relation to the involved person's maximum physical capacity (peak V'O2) and in relation to the individual aerobic-anaerobic threshold (V'O2 at VT1, t...
متن کاملTranslation, Validity, and Reliability of the Upper Extremity Fugl-Meyer Assessment (FMA-UE) in Persian Speaking Stroke Patients
Objectives: Fugl-Meyer Assessment (FMA) is the common scale for clinical and functional evaluation of sensorimotor conditions and related Upper Extremity (UE) dysfunction after stroke. This study was done to translate and cross-culturally adjust the original upper extremity FMA (FMA-UE) into Persian and to evaluate the psychometric properties of the translated version. Methods: A procedure of...
متن کاملDevelopment, Validity and Reliability of Dysphagia Assessment Test in Iranian Adults after Stroke
Introduction: Many patients who have had strokes suffer from dysphagia which can lead to aspiration pneumonia in 20% to 25% of cases. Early assessment of dysphagia has can reduce the risk of death and the cost of medical care. The present study developed a questionnaire to assess dysphagia in adult patients who have suffered strokes and determined the validity and reliability o...
متن کاملClinical assessment of fear of falling after stroke: validity, reliability and responsiveness of the Persian version of the Fall Efficacy Scale-International
Background :Fear of falling may be related to falling during stroke onset. The Fall Efficacy Scale-International (FES-I) with excellent psychometric properties, is an instrument developed to assess patients’ concerns about fallings. The aim of this study was to determine validation of this scale in Iranian patients with stroke. Methods : The “forward-backward” procedure was applied to trans...
متن کاملClinical assessment of activities of daily living in acute stroke: Validation of the Persian version of Katz Index
Background: Katz Index is a well-known index for assessing basic activities of daily living. The aim was to determine validity and reliability of the Katz Index in Iranian patients with acute stroke. Methods: Eighty-seven patients (56 male, 31 female) with acute stroke (1-30 days post-stroke) participated in this psychometric properties study. Interval time for retest was 14 days. All partic...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017