Recovery from Anemia in Patients with Severe Aortic Stenosis Undergoing Transcatheter Aortic Valve Implantation – Prevalence, Predictors and Clinical Outcome
نویسندگان
چکیده
INTRODUCTION Preoperative anemia is common in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation (TAVI) and has been linked to a poorer outcome--including a higher 1-year mortality. The aim of this study was to investigate the impact of successful TAVI on baseline anemia. METHODS A total of 253 patients who survived at least 1 year following TAVI were included in this study. The prevalence, predictors and clinical outcome of hemoglobin (Hb)-recovery were assessed. RESULTS The prevalence of baseline anemia was 49% (n = 124)--recovery from anemia occurred in 40% of the anemic patients (n = 49) at 1 year after TAVI with an increase in mean Hb-level of 1.35 g/dL from baseline. This increase was not related to an improvement in renal function. At multivariate analysis, a high peak gradient (OR 4.82, P = 0.003) was shown to be an independent predictor for Hb-recovery, while blood transfusion (OR 0.31, P = 0.038) and chronic kidney disease (CKD, OR 0.33, P = 0.043) were identified as negative predictors at, respectively, one and two years after TAVI. When compared to patients without baseline anemia, those anemic patients with Hb-recovery had a similar functional improvement (OR 0.98, P = 0.975), whereas those without Hb-recovery had a significantly lower likelihood of functional improvement with ≧2 NYHA classes (OR 0.49, P = 0.034) and a higher likelihood of re-hospitalization within the first year after TAVI (OR 1.91, P = 0.024). CONCLUSION Recovery from anemia occurs in 40% of anemic patients at 1 year after TAVI--mainly in those with a high gradient and without CKD. Blood transfusion was found to have a transient adverse effect on this Hb-recovery. Finally, anemic patients without Hb-recovery experience less functional improvement and have a higher re-hospitalization rate within the first year after TAVI.
منابع مشابه
Intervent Ions for Structural Heart D Isease
Aims: We sought to analyse local distribution of aortic annulus and left ventricular outflow tract (LVOT) calcification in patients undergoing transcatheter aortic valve replacement (TAVR) and its impact on aortic regurgitation (AR) immediately after device placement. Methods and results: A group of 177 patients with severe aortic stenosis undergoing multislice computed tomography of the aortic...
متن کاملPrognostic implications of pulmonary hypertension in patients with severe aortic stenosis undergoing transcatheter aortic valve implantation: study from the FRANCE 2 Registry.
BACKGROUND Pulmonary hypertension (PH) is associated with poor prognosis in patients with severe aortic stenosis. The aim of this multicenter study was to describe clinical outcome after transcatheter aortic valve implantation. METHODS AND RESULTS The FRANCE 2 Registry included all patients undergoing transcatheter aortic valve implantation in France in 2010 and 2011. Patients were divided in...
متن کاملRisk factors for paravalvular leak after transcatheter aortic valve implantation
Many studies have shown that transcatheter aortic valve implantation (TAVI) improves outcomes in patients with severe aortic stenosis in whom a classical surgical procedure cannot be performed due to the high risk. As one of the most frequent periprocedural complications of TAVI, paravalvular leak significantly affects the short- and long-term prognosis for patients undergoing implantation. In ...
متن کاملPredictors of clinical outcomes in patients with severe aortic stenosis undergoing TAVI: a multistate analysis.
BACKGROUND Patients with severe aortic stenosis at increased surgical risk continue to experience compromised long-term survival despite successful transcatheter aortic valve implantation. We used time-related pathways in a multistate analysis to identify predictors of adverse long-term outcome in patients who underwent transcatheter aortic valve implantation. METHODS AND RESULTS In a cohort ...
متن کاملVon Willebrand factor as a biological sensor of blood flow to monitor percutaneous aortic valve interventions.
RATIONALE Percutaneous aortic valve procedures are a major breakthrough in the management of patients with aortic stenosis. Residual gradient and residual aortic regurgitation are major predictors of midterm and long-term outcome after percutaneous aortic valve procedures. We hypothesized that (1) induction/recovery of high molecular weight (HMW) multimers of von Willebrand factor defect could ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 9 شماره
صفحات -