Accuracy of intrapartum fetal blood gas analysis by scalp sampling
نویسندگان
چکیده
Fetal blood gas analysis (FBGA) using scalp blood is commonly used to identify serious fetal distress. However, there is a lack of data regarding its accuracy and reliability. The aim of this study was to determine the positive predictive value (PPV) and negative predictive value (NPV) of FBGA for predicting postpartum acidosis in case of nonreassuring fetal heart rate tracings (NRFHRT). To this end, we conducted a retrospective cohort study of singleton term deliveries with NRFHRT according to Fédération Internationale de Gynécologie et d'Obstétrique and Fisher cardiotocography scores undergoing FBGA in a university hospital. The PPV and NPV of FBGA regarding neonatal acidosis (defined as a pH value ≤ 7.15 in arterial or venous umbilical cord blood) and Apgar scores indicating neonatal depression (defined as a 5-min Apgar score ≤5) were evaluated. Multivariate analysis was used to determine the influence of cardiotocography variations and the time delay between FBGA and delivery on the accuracy of FBGA. We analyzed 343 deliveries with NRFHRT. In 32 (9%) of these cases, fetal acidosis was confirmed by a postpartum umbilical cord blood pH value ≤ 7.15. In 308/343 (90%) cases, FBGA identified NRFHRT as false positive (as confirmed by nonacidotic postpartum pH values) and thus avoided unnecessary interventions such as operative delivery. The overall test accuracy of FBGA was 91%. FBGA accurately predicted postpartum cord blood pH values with a margin of ±0.2 in 319/343 (93%) cases. On the other hand, the false negative rate of FBGA was 8% (29/343). The PPV and NPV of FBGA for predicting postpartum acidosis were 50% and 91%, respectively. The sensitivity was 9% and the specificity was 99%. In a multivariate logistic regression analysis, maternal body mass index (odds ratio [OR] 1.1; 95% confidence interval [CI] 1.01-1.17; P = .029) and cardiotocography variations (OR 0.80; 95% CI 0.66-0.98; P = .029) independently affected the predictive value of FBGA. The PPV of FBGA regarding neonatal depression according to Apgar scores was low with only 17%. We conclude that FBGA may be used in clinical practice to rule out, but not to rule in, neonatal acidosis in parturients with NRFHRT. It can avoid unnecessary interventions such as cesarean section or operative vaginal delivery in up to 90% of cases, but cannot reliably detect fetal acidosis.
منابع مشابه
Fetal scalp pH and ST analysis of the fetal ECG as an adjunct to CTG. A multi-center, observational study.
OBJECTIVE To evaluate the relationships between scalp-pH and CTG plus ST waveform analysis of the fetal ECG (STAN) clinical guidelines as indicators of intrapartum hypoxia in term fetuses born with cord artery acidemia. STUDY DESIGN Data from 6999 term deliveries monitored by the STAN (R) S 21 as part of an EU multi-center study on clinical implementation of the STAN methodology for intrapart...
متن کاملIntrapartum Vibroacoustic Stimulation Test and Cardiotocography for the Prediction of Neonatal Outcome
Objectives: To evaluate the role of intrapartum vibroacoustic stimulation (VAST) and cardiotocography (CTG) for the prediction of neonatal outcome. Materials and methods: One hundred and twenty-five patients in labor with cephalic presentation were selected and subjected to CTG and VAST was done further to find out whether fetus is reactive or nonreactive and findings were correlated with the f...
متن کاملInfant outcome at four years of age after intrapartum sampling of scalp blood lactate for fetal assessment. A cohort study
OBJECTIVE To correlate the value of lactate in fetal scalp blood at delivery and the outcomes of the offspring at four years of age. METHODS Cases where scalp blood lactate was taken within sixty minutes before delivery were identified from the randomized trial "Determination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress". Data were grouped according to the...
متن کاملDetermination of pH or lactate in fetal scalp blood in management of intrapartum fetal distress: randomised controlled multicentre trial.
OBJECTIVE To examine the effectiveness of pH analysis of fetal scalp blood compared with lactate analysis in identifying hypoxia in labour to prevent acidaemia at birth. DESIGN Randomised controlled multicentre trial. SETTING Labour wards. PARTICIPANTS Women with a singleton pregnancy, cephalic presentation, gestational age >or=34 weeks, and clinical indication for fetal scalp blood sampl...
متن کاملRational approach to electronic fetal monitoring during labour in 'all' resource settings
Electronic fetal monitoring (EFM) involves the use of cardiotocograph (CTG) to asses fetal wellbeing during labour in order to detect intrapartum fetal hypoxia early so as to institute timely and appropriate action. Indeed, when CTG was introduced into obstetric practice in the 1960s, it was expected to prevent perinatal brain injury and reduce the incidence of short term (neonatal admissions, ...