Assessment of cross-reactivity of new less sensitizing epoxy resin monomers in epoxy resin-allergic individuals.

نویسندگان

  • Lina Hagvall
  • Ida B Niklasson
  • Johanna Rudbäck
  • Niamh M O'Boyle
  • Eva Niklasson
  • Kristina Luthman
  • Ann-Therese Karlberg
چکیده

BACKGROUND Measures to prevent occupational exposure to epoxy resins, including education, medical examination, and voluntary agreements between employers and workers, have not been effective enough to protect against skin sensitization. Therefore, alternatives to the major epoxy resin haptens that have been found to be less sensitizing in the local lymph node assay have been developed. OBJECTIVES To study the cross-reactivity of two newly designed epoxy resin monomers, with decreased skin-sensitizing potency and good technical properties as compared with diglycidyl ether of bisphenol A (DGEBA), in subjects with known contact allergy to epoxy resin of DGEBA type. PATIENTS AND METHODS Eleven individuals with previous positive patch test reactions to epoxy resin of DGEBA participated in the study. The two alternative epoxy resin monomers were synthesized and patch tested in dilution series in parallel with epoxy resin of DGEBA from the baseline series (containing 92% DGEBA). RESULTS All participants reacted to epoxy resin of DGEBA on retesting. Three participants reacted to monomer 1. No reactions were seen to monomer 2. CONCLUSIONS The alternative monomers studied showed little or no cross-reactivity with epoxy resin of DGEBA. Decreasing the risk of sensitization by using less sensitizing compounds is important, as contact allergy to epoxy resins is common in spite of thorough preventive measures.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Design and Production of Two-Piece Thyroid-Neck Phantom by the Concurrent Use of Epoxy Resin and Poly(Methyl Methacrylate) Soft Tissue Equivalent Materials

The aim of this report is to present a new two-piece thyroid-neck phantom produced by the concurrent use of epoxy resin and poly(methyl methacrylate) (PMMA: plexiglass) soft tissue equivalent materials. Accordingly, mass attenuation coefficients of the epoxy resin and the plexiglass compounds were obtained from simulation (NIST XCOM 3.1) and measurements (practical dosimetry) and compared to th...

متن کامل

Occupational allergic contact dermatitis caused by epoxy chemicals: occupations, sensitizing products, and diagnosis.

BACKGROUND Epoxy products are among the most common causes of occupational allergic contact dermatitis. Diglycidyl ether of bisphenol A resin (DGEBA-R) is the most important sensitizer in epoxy systems. OBJECTIVES To describe patients with occupational allergic contact dermatitis caused by epoxy products. METHODS Patients with allergic reactions to epoxy chemicals were chosen from test file...

متن کامل

Sensitization to reactive diluents and hardeners in epoxy resin systems. IVDK data 2002-2011. Part I: reaction frequencies.

BACKGROUND Epoxy resin systems (ERSs), consisting of resins, reactive diluents, and hardeners, are indispensable in many branches of industry. In order to develop less sensitizing ERS formulations, knowledge of the sensitizing properties of single components is mandatory. OBJECTIVES To analyse the frequency of sensitization in the patients concerned, as one integral part of a research project...

متن کامل

Influence of Curing Time and Water Content on Unconfined Compressive Strength of Sand Stabilized Using Epoxy Resin

Improvement and stabilization of soils are widely used to improve the physical and mechanical properties of sandy soils. Despite the abundance of researchers that have been conducted on this topic to date, most of them have focused on dry soil. The effects of the existing water in the soil and different curing durations (curing environment) have not been investigated. In this study, different p...

متن کامل

Two cases of occupational allergic contact dermatitis from a cycloaliphatic epoxy resin in a neat oil: Case Report

BACKGROUND Metal-working fluids contain complex mixtures of chemicals and metal workers constitute a potential risk group for the development of allergic contact dermatitis. CASE PRESENTATION Two metal workers developed allergic contact dermatitis on the hands and lower arms from exposure to a neat oil used in metal processing. Patch testing revealed that the relevant contact allergen was a c...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Contact dermatitis

دوره 75 3  شماره 

صفحات  -

تاریخ انتشار 2016