Mutagenic activity associated with by-products of drinking water disinfection by chlorine, chlorine dioxide, ozone and UV-irradiation.

نویسندگان

  • B C Zoeteman
  • J Hrubec
  • E de Greef
  • H J Kool
چکیده

A retrospective epidemiological study in The Netherlands showed a statistical association between chlorination by-products in drinking water and cancer of the esophagus and stomach for males. A pilot-plant study with alternative disinfectants was carried out with stored water of the Rivers Rhine and Meuse. It was demonstrated that the increase of direct acting mutagens after treatment with chlorine dioxide is similar to the effect of chlorination. Ozonation of Rhine water reduced the mutagenic activity for Salmonella typhimurium TA 98 both with and without metabolic activation. UV alone hardly affects the mutagenicity of the stored river water for S. typh. TA 98. In all studies, practically no mutagenic activity for S. typh. TA 100 was found. Although remarkable changes in the concentration of individual organic compounds are reported, the identity of the mutagens detected is yet unclear. Compounds of possible interest due to their removal by ozonation are 1,3,3-trimethyloxindole, dicyclopentadiene and several alkylquinolines. Compounds which might be responsible for the increased mutagenicity after chlorination are two brominated acetonitriles and tri(2-chlorethyl) phosphate. Furthermore, the concentration procedure with adsorption on XAD resin and the subsequent elution step may have affected the results. It is proposed to focus further research more on the less volatile by-products of disinfection than on the trihalomethanes.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Synergistic effects of sequential treatment by UV irradiation and chemical disinfectant for drinking water disinfection

Abstract The sequential use of disinfection strategies for drinking water treatments has been shown to provide levels of inactivation greater than those corresponding to the single-step disinfection effects (Corona-Vasquez et al., 2002; EPA, 1999). Therefore, a disinfectants combined system could be applied both for the inactivation of microorganisms, resistant to traditional treatments, and al...

متن کامل

Mutagenic activity of disinfection by-products.

Data on raw water quality, disinfection treatment practices, and the resulting mutagenic properties of the treated water were compiled from pilot- and full-scale treatment experiments to evaluate that parameter which might produce variability in the results of a mutagenic study. Analysis of the data and comparison of treatment practices indicated that the measured mutagenic activity is strongly...

متن کامل

The formation and control of emerging disinfection by-products of health concern.

When drinking water treatment plants disinfect water, a wide range of disinfection by-products (DBPs) of health and regulatory concern are formed. Recent studies have identified emerging DBPs (e.g. iodinated trihalomethanes (THMs) and acids, haloacetonitriles, halonitromethanes (HNMs), haloacetaldehydes, nitrosamines) that may be more toxic than some of the regulated ones (e.g. chlorine- and br...

متن کامل

Determination of Trace Concentrations of Oxyhalides and Bromide in Municipal and Bottled Waters Using a Hydroxide-Selective Column with a Reagent-Free Ion Chromatography System

INTRODUCTION All drinking water municipalities share the same goal of providing their communities with a reliable source of safe drinking water. To achieve this goal, most water systems must treat their water. The type of treatment used varies depending on the size, source, and water quality. Disinfection protects public water systems (PWSs) from potentially dangerous microbes. The most common ...

متن کامل

Results of toxicological testing of Jefferson Parish pilot plant samples.

Five toxicological tests were performed using concentrated drinking water samples collected at a pilot-scale drinking water treatment plant that had streams treated with different disinfectants (no disinfectant, ozone, chlorine dioxide, monochloramine, or chlorine) before treatment with granular activated carbon (GAC). The toxicological tests used in this study were the Ames Salmonella assay, a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Environmental Health Perspectives

دوره 46  شماره 

صفحات  -

تاریخ انتشار 1982