COMPACT SUPERCONDUCTING 250 MeV PROTON CYCLOTRON FOR THE PSI PROSCAN PROTON THERAPY PROJECT

نویسندگان

  • M. Schillo
  • H. Blosser
  • J.-W. Kim
  • F. Marti
چکیده

A cyclotron for proton therapy has to fulfil many requirements set by the specific operational and safety needs of a medical facility and the medical environment. These are for instance high extraction efficiency, high availability and reliability, simple and robust operation. ACCEL Instruments GmbH has refined the design concept of a medical cyclotron for the PSI PROSCAN project with the objective to use this cyclotron as the standard accelerator in complete proton therapy facilities, which ACCEL intends to market. Starting from the design in [1], we have carried out further detail clarifications, optimizations and adaptations to the needs of PSI [2]. The work was performed in a collaboration between ACCEL, NSCL and KVI in view of the requirements from the PSI PROSCAN project. An overview on the design will be given touching on subjects such as the 3D structural analysis of the coil, detailed magnetic modeling for optimization of the inner region and the spiral, optimization of the RF power, optimization of the cryogenic design based on available cryocoolers instead of a liquefaction plant and Monte Carlo simulations to estimate the heat balance produced by neutrons at 4K components.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status Report of the Accel 250 Mev Medical Cyclotron

Since 2001 a superconducting cyclotron for proton therapy has been designed in collaboration with the National Superconducting Cyclotron Laboratory (NSCL) at ACCEL Instruments GmbH [1]. The design is based on a NSCL proposal originating from 1993 [2]. In the recent years two cyclotrons of this type were built, tested as far as magnetic and cryogenic properties are concerned and installed at the...

متن کامل

Design of the Energy Selection System for Proton Thera- Py Based on Geant4*

Huazhong University of Science and Technology (HUST) has planned to build a proton therapy facility based on an isochronous superconducting cyclotron. The 250 MeV/500 nA proton beam is extracted from a superconducting cyclotron. To modulate beam energy, an energy selection system is essential in the beamline. The simulation based on Geant4 has been performed for the energy selection system and ...

متن کامل

Conceptual design of the superconducting magnet for the 250 MeV proton cyclotron

BACKGROUND The superconducting cyclotron is of great importance to treat cancer parts of the body. To reduce the operation costs, a superconducting magnet system for the 250 MeV proton cyclotron was designed to confirm the feasibility of the superconducting cyclotron. FINDINGS The superconducting magnet system consists of a pair of split coils, the cryostat and a pair of binary high temperatu...

متن کامل

Consider potential of gold nanoparticles with proton therapy compared with KV and MEV X-ray therapy.

Introduction: Many study shown the effectiveness dose enhancement with gold nanoparticles (GNPs), especially with low-energy x-rays. Recently, proton beam radiation therapy (PBRT) has attention as a treatment for tumors. The advantage in PBRT, which releases high dose at the controllable Bragg peak position that localized for Au target and the released dose increased in depth....

متن کامل

A Cw Ffag for Proton Computed Tomography

An advantage of the cyclotron in proton therapy is the continuous (CW) beam output which reduces complexity and response time in the dosimetry requirements and beam controls. A CW accelerator requires isochronous particle orbits at all energies through the acceleration cycle and present compact isochronous cyclotrons for proton therapy reach only 250 MeV (kinetic energy) which is required for p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001