Reproducibility of anterior chamber angle analyses with the swept-source optical coherence tomography in young, healthy Caucasians.
نویسندگان
چکیده
PURPOSE To assess the reproducibility of iridocorneal angle (ICA) analysis in young, healthy Caucasian subjects using swept-source optical coherence tomography (SS-OCT) by determining variability and interobserver agreement between expert and nonexpert observers. METHODS Thirty-one healthy volunteers (nonexperts) acquired three consecutive SS-OCT images of the right eyes of their peer nonexperts. Images were analyzed by 31 nonexperts and additionally by three experts, whereby the angle opening distance (AOD) and the trabecular iris space area (TISA) at 500 and 750 μm were calculated. A random intercept model was used to determine the amount of variation between observers. In addition, the intra-observer variability between nonexperts and experts was calculated by determining the coefficient of variation (CV). RESULTS A significant difference was found in the expert analysis for the nasal and temporal angle in the AOD500 (P = 0.002), AOD750 (P < 0.01), and TISA750 (P < 0.01), and the values AOD500 (P = 0.025), AOD750 (P = 0.012), and TISA500 (P = 0.010) were significantly larger if nonexperts analyzed SS-OCT images. The CV was only significant larger for nonexperts for AOD500 (11.1% vs. 8.7%, P < 0.01). CONCLUSIONS This study demonstrated high reproducibility of angle analysis in young, healthy Caucasian subjects using SS-OCT. Nevertheless, nonexperts obtained significant larger values compared with experts, implying that training is a necessary requirement before analyzing SS-OCT images in ophthalmic practice.
منابع مشابه
Anterior chamber angle imaging with swept-source optical coherence tomography: an investigation on variability of angle measurement.
PURPOSE To evaluate the reproducibility of anterior chamber angle measurements obtained by swept-source optical coherence tomography (OCT) and to identify factors associated with its measurement variability. METHODS One eye from each of 30 healthy subjects was randomly selected for anterior segment OCT imaging (Casia SS-1000 OCT; Tomey, Nagoya, Japan) in three separate visits within a week. T...
متن کاملReference values for anterior chamber morphometrics with swept-source optical coherence tomography in a Caucasian population
Purpose The aim of this study is to generate reference values for anterior chamber morphometrics to facilitate the interpretation of anterior chamber images acquired with swept-source optical coherence tomography (SS-OCT) in a Caucasian population. Materials and methods Non-glaucomatous Caucasian subjects, who were newly referred to the outpatient department of the University Eye Clinic Maast...
متن کاملAssessment of Anterior Segment Measurements with Swept Source Optical Coherence Tomography before and after Ab Interno Trabeculotomy (Trabectome) Surgery
Purpose. To compare the changes of anterior segment parameters, assessed by swept source anterior segment optical coherence tomography (AS-OCT) after combined Trabectome-cataract surgery and Trabectome-only surgery in open angle glaucoma patients. Methods. Thirty-eight eyes of 24 patients with open angle glaucoma were scanned with swept source AS-OCT before and 4 weeks after combined Trabectome...
متن کاملComparisons of anterior segment biometry between Chinese and Caucasians using anterior segment optical coherence tomography.
PURPOSE To compare anterior segment parameters between eyes of Chinese and Caucasians using anterior segment optical coherence tomography and to evaluate the association between these parameters and anterior chamber angle width between the two ethnic groups. METHODS 60 Chinese and 60 Caucasians, 30 with open angles and 30 with narrow angles (defined as Shaffer grade < or =2 in > or =3 quadran...
متن کاملAnterior Chamber Measurements by Pentacam and AS-OCT in Eyes With Normal Open Angles
PURPOSE To assess the reproducibility and agreement of anterior chamber measurements between the Pentacam (PTC) and the Anterior segment optical coherence tomography (AOCT) in normal healthy eyes with open angle. METHODS Prospective cross-sectional comparative case series. A total of 162 eyes of 81 healthy volunteers with normal open angle were included in this study. Anterior chamber angle (...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Investigative ophthalmology & visual science
دوره 55 6 شماره
صفحات -
تاریخ انتشار 2014