Hypercholesterolemia is associated with visual field alterations detectable with computerized perimetry.
نویسندگان
چکیده
Computerized perimetry analysis of the visual field enables the capacity of the visual cortex to process the electric impulse received from the eyeball to be detected. Considering that hypercholesterolemia can cause cognitive worsening by altering the functioning of the cerebral cortex, we attempted to determine whether it can affect the cortical processing of the visual stimuli, as detected by computerized perimetry. We undertook computerized perimetry analysis of 208 male and female patients (mean age, 48.5 years) with plasma low density lipoprotein (LDL) cholesterol concentrations above 3.36 mmol/L and compared the results with the same number of matched controls with LDL cholesterol concentrations below 3.36 mmol/L. No subject had any neuro-ophthalmological disease that could have affected the results. A Humphrey 745 computerized perimetry device was used to measure the mean deviation, the pattern standard deviation, the corrected pattern standard deviation, short-term fluctuations and the foveal threshold. Compared with the control subjects, the patients with hypercholesterolemia showed worsening in all the perimetry variables analyzed. Moreover, we also found a direct association between plasma LDL cholesterol concentrations and the perimetry alterations, and an inverse association between these alterations and the figures for HDL cholesterol. Our data show that computerized perimetry can detect alterations in the visual field of persons with hypercholesterolemia, suggesting that increased plasma concentrations of cholesterol may have a negative influence on the visual neuron cells.
منابع مشابه
Subclinical visual field alterations are commonly present in patients with Graves' Orbitopathy and are mainly related to the clinical activity of the disease.
The present study was aimed to investigate optic nerve involvement by computerized perimetry in 40 (29 women, 11 men) consecutive GO patients not showing definite dysthyroid optic neuropathy (DON). All patients presenting visual acuity defects, pallor or swelling of the optic nerve, concomitant eye disease, evidence of apical crowding or optic nerve stretching at either MRI or CT imaging were e...
متن کاملThe Comparison before and after Excision of Sella Supra Sellar Tumors by Performing the Pre and Post-op Computerized Perimetry
.. Objectives: To obtain and compare the exact visual status before and after excision of sella supra sellar tumors using the computerized perimetry as a standard measuring tools and then compare with the international studies. Background: Sella suprasellar tumors are though not so common but affect visual acuity of patients and their quality of life drops. These tumors include pituitary adenom...
متن کاملRetinal function abnormalities in patients treated with vigabatrin.
OBJECTIVE To evaluate central and peripheral retinal function in patients treated with vigabatrin, an antiepileptic drug associated with peripheral visual field constriction (VFC). METHODS Six patients with epilepsy treated with vigabatrin as add-on therapy for at least 3 years were included in this observational case series. All patients underwent a clinical ophthalmologic examination, color...
متن کاملBehavioral perimetry in monkeys.
PURPOSE Normative data on the systematic changes in visual sensitivity as a function of retinal eccentricity have provided the basis for efficient threshold strategies and data analysis routines for static perimetry. The standard methods of assessing visual field changes in patients also could be used for monkeys with experimentally induced ocular disorders if the normal visual fields of monkey...
متن کاملFalse-negative responses in glaucoma perimetry: indicators of patient performance or test reliability?
PURPOSE To study whether false-negative answers in computerized glaucoma perimetry indicate the patient's ability to perform perimetry or test result reliability. METHODS A retrospective evaluation was performed of visual field test results obtained with a perimetry program (Humphrey 30-2 Sita Standard; Humphrey Instruments, San Leandro, CA) in 70 consecutive patients with unilateral glaucoma...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Atherosclerosis
دوره 195 1 شماره
صفحات -
تاریخ انتشار 2007