Te neutrinoless double-beta decay with CUORICINO

نویسندگان

  • E. Andreotti
  • S. Di Domizio
  • M. Vignati
چکیده

We report the final result of the CUORICINO experiment. Operated between 2003 and 2008, with a total exposure of 19.75 kg . y of Te, CUORICINO was able to set a lower bound on the Te 0mbb half-life of 2.8 x 10 years at 90% C.L. The limit here reported includes the effects of systematic uncertainties that are examined in detail in the paper. The corresponding upper bound on the neutrino Majorana mass is in the range 300–710 meV, depending on the adopted nuclear matrix element evaluation.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Status of Cuore experiment and last results from Cuoricino

CUORE is a cryogenic-bolometer detector consisting of 988 TeO 2 crystals, 750 g each, operated at a temperature of ∼8 mK, currently under construction in the underground Laboratori Nazionali del Gran Sasso. Its goal is to search for neutrinoless double beta decays with a sensitivity to the effective neutrino mass as low as a few tens of meV. CUORICINO, its pilot experiment, has proven the feasi...

متن کامل

Cryogenic Double Beta Decay Experiments: CUORE and CUORICINO

Cryogenic bolometers, with their excellent energy resolution, flexibility in material, and availability in high purity, are excellent detectors for the search for neutrinoless double beta decay. Kilogram-size single crystals of TeO2 are utilized in CUORICINO for an array with a total detector mass of 40.7 kg. CUORICINO currently sets the most stringent limit on the halflife of Te of T 1/2 ≥ 2.4...

متن کامل

Potential and Prospects for CUORE and CUORICINO experiments

The CUORE (Cryogenic Underground Observatory for Rare Events) experiment projects to construct and operate an array of 1000 cryogenic thermal detectors of a mass of 760 g each to investigate rare events physics, in particular, double beta decay and non baryonic particle dark matter. A first step towards CUORE is CUORICINO, an array of 56 of such bolometers, currently being installed in the Gran...

متن کامل

Further developments in the CUORICINO experiment

We report the present results of the CUORICINO experiment, a cryogenic experiment on neutrinoless Double Beta Decay (DBD) of Te consisting of an array of 62 TeO2 crystals with a total active mass of 40:7 kg. The array is framed inside a dilution refrigerator, heavily shielded against environmental radioactivity and high-energy neutrons, and it is operated at a temperature of 8 mK in the Gran Sa...

متن کامل

Muon-induced backgrounds in the CUORICINO experiment

a r t i c l e i n f o a b s t r a c t Keywords: CUORICINO Muons Cosmic rays Double beta decay Neutrinos To better understand the contribution of cosmic ray muons to the CUORICINO background, 10 plastic scintillator detectors were installed at the CUORICINO site and operated during the final 3 months of the experiment. From these measurements, an upper limit of 0.0021 counts/(keV kg yr) (95% CL)...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2012