Mass Spectrometric Data of Commonly Abused Amphetamines and Their Derivatives - Cross Contribution of Ion Intensity between the Analytes and Their Isotopically Labeled Analogs.
نویسندگان
چکیده
With GC-MS as the preferred method and isotopically labeled analogs of the analytes as the internal standards (ISs) of choice for the analysis of drugs/metabolites in biological specimens, one important aspect associated with chemical derivatization (CD) is that the CD products derived from the analyte and the selected IS must generate ions suitable for designating the analyte and the IS; these ions cannot have significant crosscontribution (CC), i.e., contribution to the intensity of the ion designated for the analyte by the IS, and vice versa. With this in mind, the authors have reviewed literature and commercial information on common CD reagents and methods and conducted a thorough search of isotopically labeled analogs of commonly abused amphetamine-type drugs/metabolites that are commercially available. These ISs and analytes were then derivatized with various derivatization groups. These CD products were then analyzed by GC-MS and the resulting MS data are presented here in two forms: (a) systematic presentation of full-scan spectra; and (b) tabulation of CC data for ions with potential for designating the ISs and analytes. Many (if not most) of these full-scan spectra are not yet available in the literature and should be of daily reference value to forensic and clinical laboratories that are engaged in the analysis of these drugs/metabolites. Full-scan MS data were further used to select ion-pairs with potential for designating the analytes and ISs in quantitative analysis protocols. The CC data of these ion-pairs were evaluated using data collected under the SIM mode and summarized in table format. These data should save enormous amounts of time and efforts for practicing laboratories in their search for this analytical parameter.
منابع مشابه
Mass Spectra and Cross-Contribution of Ion Intensity Between Drug Analytes and Their Isotopically Labelled Analogs - Benzodiazepines and Their Derivatives.
With GC-MS as the preferred method and isotopically labeled analogs (ILAs) of the analytes as the internal standards (ISs) of choice for quantitative determination of drugs/metabolites in biological specimens, one important aspect associated with chemical derivatization (CD) is that the CD products derived from the analyte and the selected IS must generate ions suitable for designating the anal...
متن کاملIsotopic analogues as internal standards for quantitative analyses of drugs and metabolites by GC-MS--nonlinear calibration approaches.
In order to achieve accurate quantitation of drugs and metabolites (analytes) in complex matrices, 2H- (and less commonly 13C-) labeled analogues of the analytes are now routinely adapted as the internal standards (IS) using linear calibration models to fit data generated by selected ion monitoring gas chromatography-mass spectrometry (GC-MS) protocols. In this study, the effects of cross-contr...
متن کاملFlame atomic absorption spectrometric determination of Cd(II), Zn(II) and Ag(I) in different matrixes after solid phase extraction on sodium dodecyl sulfate (SDS)-coated alumina as their 2,3 Di Hydro 2,3 para tolyl Qinazoline (1 H)- 4 one (DPTQO)
A sensitive and selective solid phase extraction procedure for the determination of traces of Cd(II),Zn(II) and Ag(I) ions has been developed. An alumina-sodium dodecyl sulfate (SDS) coated on with2,3 Di Hydro 2,3 para tolyl Qinazoline (1 H)- 4 one (DPTQO). The influences of the analyticalparameters including pH and sample volume were investigated. Common coexisting ions did notinterfere on the...
متن کاملDetector response and intensity cross-contribution as contributing factors to the observed non-linear calibration curves in mass spectrometric analysis.
It is a common knowledge that detector fatigue causes a calibration curve to deviate from the preferred linear relationship at the higher concentration end. With the adaptation of an isotopically labeled analog of the analyte as the internal standard (IS), cross-contribution (CC) of the intensities monitored for the ions designating the analyte and the IS can also result in a non-linear relatio...
متن کاملIonization Suppression and Recovery in Direct Biofluid Analysis Using Paper Spray Mass Spectrometry.
Paper spray mass spectrometry is a method for the direct analysis of biofluid samples in which extraction of analytes from dried biofluid spots and electrospray ionization occur from the paper on which the dried sample is stored. We examined matrix effects in the analysis of small molecule drugs from urine, plasma, and whole blood. The general method was to spike stable isotope labeled analogs ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Forensic science review
دوره 17 2 شماره
صفحات -
تاریخ انتشار 2005