Calibrating airborne measurements of airspeed, pressure and temperature using a Doppler laser air-motion sensor

نویسندگان

  • W. A. Cooper
  • S. M. Spuler
چکیده

A new laser air-motion sensor measures the true airspeed with a standard uncertainty of less than 0.1 m s−1 and so reduces uncertainty in the measured component of the relative wind along the longitudinal axis of the aircraft to about the same level. The calculated pressure expected from that airspeed at the inlet of a pitot tube then provides a basis for calibrating the measurements of dynamic and static pressure, reducing standard uncertainty in those measurements to less than 0.3 hPa and the precision applicable to steady flight conditions to about 0.1 hPa. These improved measurements of pressure, combined with high-resolution measurements of geometric altitude from the global positioning system, then indicate (via integrations of the hydrostatic equation during climbs and descents) that the offset and uncertainty in temperature measurement for one research aircraft are +0.3± 0.3 C. For airspeed, pressure and temperature, these are significant reductions in uncertainty vs. those obtained from calibrations using standard techniques. Finally, it is shown that although the initial calibration of the measured static and dynamic pressures requires a measured temperature, once calibrated these measured pressures and the measurement of airspeed from the new laser air-motion sensor provide a measurement of temperature that does not depend on any other temperature sensor.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی پارامترهای عمل‌کردی اتاق‌های پاک (مطالعه موردی در یک صنعت دارویی)

Introduction: Nowadays, many modern industries require an environment with no contamination by particles and bacteria. An enclosed clean room environment is a place where parameters such as airborne particles, temperature, humidity, air pressure and air flow pattern is controlled. The aim of this study was to evaluate functional parameters of a clean room  in a selected pharmaceutical industry....

متن کامل

Comparative Optical Measurements of Airspeed and Aerosols on a DC-8 Aircraft

NASA Dryden supported a cooperative flight test program on the NASA DC-8 aircraft in November 1993. This program evaluated optical airspeed and aerosol measurement techniques. Three brassboard optical systems were tested. Two were laser Doppler systems designed to measure freestream-referenced airspeed. The third system was designed to characterize the natural aerosol statistics and airspeed. T...

متن کامل

Investigation of Behavior and Trend of Nitrogen Dioxide in Tehran Using OMI Satellite Sensor Measurements

Air pollution is one of the most important problems in the world’s major cities in the last century because it endangers human health and the environment. One of the indicators of air pollution is nitrogen dioxide, which is continuously measured by satellite from space and via ground-based instruments. In this paper, the data for nitrogen dioxide was measured by OMI over Tehran. Wind, surface t...

متن کامل

Influence of Airspeed Measurement Error – Implications for Dead Reckoning Navigation

Errors in navigational instruments can significantly affect flight safety. Airspeed is a key piece of navigational data that depends on accurately measured air pressure, which in turn depends on accurately measured air temperature. Instead of measuring the outside air temperature in real time, cockpit instruments are preprogramed with standard air temperature values for different flight altitud...

متن کامل

Absolute and differential measurement of water vapor supersaturation using a commercial thin-film sensor

We describe a technique for measuring the water vapor supersaturation of normal air over a temperature range of 240&T&0 °C. The measurements use an inexpensive commercial hygrometer which is based on a thin-film capacitive sensor. The time required for the sensor to reach equilibrium was found to increase exponentially with decreasing sensor temperature, exceeding 2 min for T5230 °C; however, t...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014