Single-Shot Spiral Chemical Shift Imaging in the Rat In Vivo with Hyperpolarized [1-C]-Pyruvate
نویسندگان
چکیده
shot spCSI in 125 ms. Color scale is the same for all images (with Pyr scaled down by 2.5), threshold at 15% of maximum. (b) Same as (a), but acquired with FIDCSI (Tacq = 24 s). Fig. 2: Time courses of the average signal intensity from ROIs in the left kidney (solid) and heart (dashed) for Pyr (blue circle), Lac (red square), and Ala (green cross). The time courses for Pyr are scaled down by a factor of 8. Single-Shot Spiral Chemical Shift Imaging in the Rat In Vivo with Hyperpolarized [1-C]-Pyruvate
منابع مشابه
In vivo single-shot 13C spectroscopic imaging of hyperpolarized metabolites by spatiotemporal encoding.
Hyperpolarized metabolic imaging is a growing field that has provided a new tool for analyzing metabolism, particularly in cancer. Given the short life times of the hyperpolarized signal, fast and effective spectroscopic imaging methods compatible with dynamic metabolic characterizations are necessary. Several approaches have been customized for hyperpolarized (13)C MRI, including CSI with a ce...
متن کامل3D cardiac Chemical Shift Imaging of [1-13C] hyperpolarized acetate and pyruvate in pigs
Background 13C Dynamic Nuclear Polarization (DNP) with rapid dissolution together with Magnetic Resonance Chemical Shift Imaging (CSI) have been used for non-invasive real-time metabolic assessment in cardiac experimental models on a clinical 3T scanner. Here, we report an in vivo comparison of hyperpolarized [1-13C] pyruvate and [1-13C] acetate perfusion and metabolism: a method based on a 3D ...
متن کاملMetabolic Imaging of the Perfused Rat Heart Using Hyperpolarized [1-13C]Pyruvate
Introduction : The recent development of liquid state Dynamic Nuclear Polarization (DNP) techniques has dramatically increased the signal available from C MRS experiments and has opened up new possibilities for metabolic imaging of the heart [1]. Oxidative decarboxylation of DNP hyperpolarized [1-C]pyruvate, mediated by the pyruvate dehydrogenase (PDH) complex, is a critical reaction that produ...
متن کاملFast metabolic imaging of systems with sparse spectra: application for hyperpolarized 13C imaging.
A fast spiral chemical shift imaging (spCSI) sequence was developed for application to hyperpolarized (13)C imaging. The sequence exploits sparse spectra, which can occur in such applications, and prior knowledge of resonance frequencies to reduce the measurement time by undersampling the data in the spectral domain. As a consequence, multiple reconstructions of a given data set have to be comp...
متن کاملSaturation-recovery metabolic-exchange rate imaging with hyperpolarized [1-13C] pyruvate using spectral-spatial excitation.
Within the last decade hyperpolarized [1-13C] pyruvate chemical-shift imaging has demonstrated impressive potential for metabolic MR imaging for a wide range of applications in oncology, cardiology, and neurology. In this work, a highly efficient pulse sequence is described for time-resolved, multislice chemical shift imaging of the injected substrate and obtained downstream metabolites. Using ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -