Meniscal allograft size can be predicted by height, weight, and gender.
نویسندگان
چکیده
PURPOSE Our purpose was to determine if height, weight, and gender can be used to accurately predict proper meniscal allograft dimensions. METHODS Data were obtained from the Joint Restoration Foundation (AlloSource, Centennial, CO) regarding meniscal size and patient characteristics from meniscal donors. Donor height, weight, sex, age, and anatomic meniscal dimensions were recorded for 930 donor menisci in 664 patients. Multivariate regressions were completed using gender, height, and weight as independent variables and lateral meniscus length, lateral meniscus width, medial meniscus length, and medial meniscus width as dependent variables. The regression formulas were then reapplied to the data in order to produce estimated meniscus dimensions based on donor height, weight, and gender. A 90:10 split of the data was used to validate the regression models. Predicted meniscal size was then compared to actual meniscal size and the results compared to current measurement techniques. RESULTS Regression formulas showed the ability to predict meniscal size based on gender, height, and weight with standard deviations (SDs) equal to or less than current radiographic techniques (SD, 6.4% to 8.2%). Average differences between predicted size and actual size ranged from 5.2% to 6.5% for length and 5.2% to 6.0% for width. Patient height was found to be a much more powerful predictor of meniscal size than patient weight. Data from the 90:10 split of data validated the model on an independent sample. These validated outputs were then compared to contemporary techniques and found to have lower SDs and average error rates in the majority of cases. CONCLUSIONS We have proposed a validated regression model that uses height, weight, and gender variables to accurately predict required allograft meniscal size. We compared it against previously published data for radiographic and magnetic resonance imaging sizing techniques and found it to produce results that were, overall, slightly more accurate. CLINICAL RELEVANCE This model provides a novel method for sizing meniscal allografts.
منابع مشابه
Meniscal sizing based on gender, height, and weight.
PURPOSE Successful meniscus transplantation may depend on accurate sizing. Meniscal sizing is currently determined by measuring a combination of bony landmarks and soft-tissue insertion points through images obtained radiographically or by magnetic resonance imaging (MRI). The literature widely reports inaccuracy in sizing resulting from radiographic errors in magnification, erroneous identific...
متن کاملThe Relationship between Birth Weight, Birth Height, and Dental Development by Demirjian’s Method
Introduction: Like other measures of human development, dental development is not in complete accordance to chronological age. Investigations show that dental age can be affected by gender, race, systemic conditions, and some other factors and consequently, be different in people of the same chronological age. A correct estimation of dental age and its development in children is of great import...
متن کاملContact Mechanics of the Medial
The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an...
متن کاملEffect of lateral meniscal allograft sizing on contact mechanics of the lateral tibial plateau: an experimental study in human cadaveric knee joints.
BACKGROUND A mismatch of the original lateral meniscus and a lateral meniscus allograft by inaccurate preoperative radiographic sizing can have significant consequences on ultimate function. HYPOTHESIS The size of a lateral meniscal allograft affects the contact mechanics of the femoral condyle on the tibial plateau. STUDY DESIGN Controlled laboratory study. METHODS Four right and 2 left ...
متن کاملContact mechanics of the medial tibial plateau after implantation of a medial meniscal allograft. A human cadaveric study.
The goal of this study was to determine how well a medial meniscal allograft restores the normal contact mechanics of the medial tibial plateau at the time of implantation. We measured maximum pressure, mean pressure, and contact area of the intact human cadaveric knee, the knee after meniscectomy, the knee with the original meniscus removed and reimplanted as an autograft, and the knee with an...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Arthroscopy : the journal of arthroscopic & related surgery : official publication of the Arthroscopy Association of North America and the International Arthroscopy Association
دوره 25 7 شماره
صفحات -
تاریخ انتشار 2009