Effect of contact lens material on cytotoxicity potential of multipurpose solutions using human corneal epithelial cells
نویسندگان
چکیده
PURPOSE Multipurpose solutions (MPS) are used daily to clean and disinfect silicone hydrogel (SiHy) contact lenses. This in vitro study was undertaken to identify the potential for interaction between MPS, SiHy surface treatments, and lens materials, which may lead to changes in the response of human corneal epithelial cells (HCEC) to MPS-soaked lenses. METHODS The MPS tested were renu fresh (formerly known as ReNu MultiPlus; ReNu), OptiFree Express (OFX), OptiFree RepleniSH, SoloCare Aqua, and Complete Moisture Plus. The SiHy materials evaluated were lotrafilcon A, lotrafilcon B, comfilcon A, galyfilcon A, and balafilcon A (BA). MPS-soaked lenses were placed on top of adherent HCEC. The effect of MPS dilutions (0.1 to 10% final concentration in medium) was also characterized. Cell viability, adhesion phenotype and caspase activation were studied after 24-h cell exposure. OFX released from lenses was determined using UV absorbance. RESULTS A significant reduction in viability (between 30 to 50%) was observed with cells exposed to lenses soaked in ReNu and OFX. A significant downregulation of α(3) and β(1) integrins, with integrin expression ranging from 60% to 75% of control (cells with no lens), was also observed with OFX and ReNu-soaked lenses. With the exception of BA, all other lenses soaked in OFX resulted in significant caspase activation, whereby over 18% of cells stained positive for caspases. Minimal caspase activation was observed in cells exposed to ReNu and Solo soaked lenses. For both OFX and ReNu, exposing cells to at least a 5% dilution had a significant effect on viability and integrin expression. While Complete and Solo did not lead to reduction in viability, cells exposed to a 10% dilution showed reduced integrin expression down to less than 70% of control value. Comparing cell response to diluted MPS solutions and various MPS-soaked lenses showed that it is not possible to reliably use cell response to MPS dilution alone to assess MPS biocompatibility. CONCLUSIONS Our results demonstrate that the reaction of HCEC to MPS are affected by the type of lenses the MPS is released from and may potentially be influenced by the surface treatment (or lack of it) of SiHy materials.
منابع مشابه
Efficacy of Korean Multipurpose Contact Lens Disinfecting Solutions against Acanthamoeba castellanii
Acanthamoeba keratitis has been increasing in recent years. Main risk factors are contact lens wear and their cleaning solutions. Most contact lens wearers use multipurpose disinfecting solutions (MPDS) for cleansing and disinfecting microorganisms because of its convenience. We determined amoebicidal effects of MPDS made in Korea and their cytotoxicity on human corneal epithelium cells. Fiftee...
متن کاملThe clinical and cellular basis of contact lens-related corneal infections
Microbial keratitis (MK) is the most visually devastating complication associated with contact lens wear. Pseudomonas aeruginosa (PA) is highly invasive in the corneal epithelium and is responsible for more than half of the reported cases of contact lens-related MK. To protect against Pseudomonas-mediated MK, the corneal epithelium has evolved overlapping defense mechanisms that function to pro...
متن کاملA novel mechanism of increased infections in contact lens wearers.
PURPOSE It is well documented that contact lens wearers have much higher incidences of corneal infections compared with those of non-contact lens wearers, although the exact cause(s) of this increased susceptibility has not been identified. A distinct subset of mucins (MUCs) is present on the ocular surface, acting to protect the integrity of the corneal epithelium. This study was performed to ...
متن کاملOcular cytotoxicity evaluation of medical devices such as contact lens solutions and benefits of a rinse step in cleaning procedure.
Contact lens care solutions are known to have toxic effects on the ocular surface. The ISO 10993-5 standard describes test methods to assess the cytotoxicity of medical devices, but it needs some improvements to discriminate contact lens care multipurpose solutions. First we evaluated the biological hazards associated with the use of ophthalmic solutions, running a collaborative study with the ...
متن کاملCorneal Cell Adhesion to Contact Lens Hydrogel Materials Enhanced via Tear Film Protein Deposition
Tear film protein deposition on contact lens hydrogels has been well characterized from the perspective of bacterial adhesion and viability. However, the effect of protein deposition on lens interactions with the corneal epithelium remains largely unexplored. The current study employs a live cell rheometer to quantify human corneal epithelial cell adhesion to soft contact lenses fouled with the...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 17 شماره
صفحات -
تاریخ انتشار 2011